M800S/M80 Series Connection and Setup Manual
7 Connection of Control Unit
191
IB-1501269-F
7.6.1 Connecting with Drive Unit MDS-E/EH Series
(1) When Using One Power Supply Unit
Connect the largest-capacity spindle drive unit to the final axis of the NC communication bus in order to control the
power supply unit. The spindle drive unit must be installed adjacent to the power supply unit. In the system with
servo only, a servo drive unit for controlling unbalance axis must be installed in the same manner in the same way.
< Connection >
CN1A : CN1B connector on NC or previous stage's drive unit
CN1B : CN1A connector on next stage's drive unit
CN4 : Connector for communication between power supply unit (master side) and drive unit
Connection when using one power supply unit
CAUTION
1. Connect the NC and the drive units by the optical communication cables. The distance between the NC and the
final drive unit must be within 30m and the bending radius within 80mm.
2. For the main circuit wiring of the drive unit and power supply unit, the drive unit of 200V series is to be wired
with MDS-D2-CV, and the drive unit of 400V series is to be wired with MDS-EH-CV.
3. A spindle drive unit that controls the high-speed synchronous tapping (OMR-DD control) has to be connected
on the farther side from the NC than the servo drive unit that is subject to the synchronous tapping control.
POINT
Axis Nos. are determined by the rotary switch for setting the axis No. (Refer to section "Setting the rotary
switch".) The axis No. has no relation to the order for connecting to the NC.
CN4
CN4
Refer to the
instruction manual
of each NC for
details.
The optical communication cables from the NC to the
final drive unit must be within 30m.
Optical
communication
cable
Connected
to the NC
MDS-E/EH-V2
1st/2nd axis
MDS-E/EH-V1
3rd axis
MDS-E/EH-SP
6th axis
(Final axis)
MDS-E/EH-CV
MDS-E-SP2
4th/5th axis
Summary of Contents for M80 series
Page 1: ......
Page 4: ......
Page 9: ......
Page 21: ......
Page 23: ......
Page 25: ......
Page 27: ......
Page 29: ......
Page 37: ......
Page 38: ...1 IB 1501269 F 1 System Basic Configuration...
Page 40: ...3 IB 1501269 F 2 General Connection Diagram...
Page 44: ...7 IB 1501269 F 3 List of Configuration...
Page 53: ...M800S M80 Series Connection and Setup Manual 3 List of Configuration 16 IB 1501269 F...
Page 54: ...17 IB 1501269 F 4 General Specifications...
Page 185: ...M800S M80 Series Connection and Setup Manual 4 General Specifications 148 IB 1501269 F...
Page 186: ...149 IB 1501269 F 5 Installation...
Page 211: ...M800S M80 Series Connection and Setup Manual 5 Installation 174 IB 1501269 F...
Page 212: ...175 IB 1501269 F 6 Precautions for Connecting...
Page 219: ...M800S M80 Series Connection and Setup Manual 6 Precautions for Connecting 182 IB 1501269 F...
Page 220: ...183 IB 1501269 F 7 Connection of Control Unit...
Page 245: ...M800S M80 Series Connection and Setup Manual 7 Connection of Control Unit 208 IB 1501269 F...
Page 246: ...209 IB 1501269 F 8 Connection of Keyboard Unit...
Page 248: ...211 IB 1501269 F 9 Connection of Operation Panel I O Unit...
Page 262: ...225 IB 1501269 F 10 Connection of Remote I O Unit...
Page 289: ...M800S M80 Series Connection and Setup Manual 10 Connection of Remote I O Unit 252 IB 1501269 F...
Page 290: ...253 IB 1501269 F 11 Connection of Manual Pulse Generator...
Page 294: ...257 IB 1501269 F 12 Connection of Synchronous Feed Encoder...
Page 296: ...259 IB 1501269 F 13 Connection of MITSUBISHI CNC Machine Operation Panel...
Page 308: ...271 IB 1501269 F 14 Connection of Handy Terminal...
Page 310: ...273 IB 1501269 F 15 Cable...
Page 349: ...M800S M80 Series Connection and Setup Manual 15 Cable 312 IB 1501269 F...
Page 350: ...313 IB 1501269 F 16 Setup Outline...
Page 354: ...317 IB 1501269 F 17 Setting the Hardware...
Page 383: ...M800S M80 Series Connection and Setup Manual 17 Setting the Hardware 346 IB 1501269 F...
Page 384: ...347 IB 1501269 F 18 Setting Up with M80 M800S SETUP INSTALLER...
Page 392: ...355 IB 1501269 F 19 Setting the Parameters and Date Time...
Page 398: ...361 IB 1501269 F 20 PLC Program Writing...
Page 410: ...373 IB 1501269 F 21 Confirming the Basic Operation...
Page 416: ...379 IB 1501269 F 22 Setting the Position Detection System...
Page 440: ...403 IB 1501269 F 23 Setting the Tool Entry Prohibited Range...
Page 454: ...417 IB 1501269 F 24 Confirming the Spindle Operation...
Page 458: ...421 IB 1501269 F 25 Setting the Handy Terminal...
Page 464: ...427 IB 1501269 F 26 Setting the Deceleration Check...
Page 474: ...437 IB 1501269 F 27 Adjust S analog Screen...
Page 479: ...M800S M80 Series Connection and Setup Manual 27 Adjust S analog Screen 442 IB 1501269 F...
Page 480: ...443 IB 1501269 F 28 Device Open Parameter Screen...
Page 486: ...449 IB 1501269 F 29 SRAM Open Parameter Screen...
Page 492: ...455 IB 1501269 F 30 Data Backup and Restoration...
Page 498: ...461 IB 1501269 F 31 Appx 1 Setting the System Lock...
Page 502: ...465 IB 1501269 F 32 Appx 2 Protection Setting...
Page 510: ...473 IB 1501269 F 33 Appx 3 Displaying Original Logo On Standard Screen...
Page 512: ...475 IB 1501269 F 34 Appx 4 EMC Installation Guidelines...
Page 524: ...487 IB 1501269 F 35 Appx 5 Restrictions for Lithium Batteries...
Page 532: ...495 IB 1501269 F 36 Appx 6 Precautions for Compliance to UL c UL Standards...
Page 538: ......
Page 542: ......