46
11.1 I / O Specifications
Items
Terminal
Specifications
Power
supplies
Input
PSL
100 ~ 240V AC +10 ~ –15% 50/60 Hz 400VA
Power fuse (250V 8A) built in
Allowable instantaneous power interruption:10ms
PSN
Output
S1(+)
Auxiliary power supply: 12 VDC, 2 A, Rating: 10 s
S2(–)
RED(+)
Power supply for tension detectors
BLK(–)
+5V(+)
Service power supply for external trimmer
5V DC, 50mA or less
AIC(–)
Contact
signals
Input
MCC
Contact input common terminal
8V DC,
4mA/terminal
MC1
Operation/stop
ON=Automatic operation, OFF=Stop
MC2
Reel exchange signal
OFF=Reel A, ON=Reel B
MC3
Gain 1 Gain 1 is effective during ON.
MC4
Stall memory reset
One-shot input for approx. 0.5 s
MC5
Gain2
: Gain 2 is effective during ON.
Inching
: Lower output limit is effective.
Stall memory update is stopped.
OUT remote : Control output is ON during ON.
Cut torque
: Lower output limit is effective during ON
(for cutter).
Each function is assigned by parameter.
MC6
Output
ZT
• Zero tension detection output.
Set value : 0~1999 N (199.9 kgf)
• Output becomes ON when tension does not exceed set value.
• Output is always OFF when "0" is set. (However, output becomes ON
regardless of set value and tension when watch dog timer is actuated.)
• 250V AC, 0.5A or 30V DC, 0.5A
ZT
Analog
signals
Input
GRL
Left
Tension detector signal. GR=green, WH=white
• Number of detectors(one or two) is specified by parameter.
• Connection varies depending on load type(compression or ten-
sion).
• When one detector exclusively is used,terminals[GRL] and
[WHL] must be short-circuited.
WHL
GRR
Right
WHR
AI1
External tension setting
0 ~ 5 VDC corresponding to 0 ~ full-scale tension
Internal resistance
: 100 k
Ω
Recommended trimmer: 10 k
Ω
AIC
11. Specifications