50
11.4 Selection item and analog data
-------- The items cannot set during operation.
*1 : Refer to the note in the previous page.
*2 : Setting of MC5, MC6
When the control reel is set to one reel or the feed reel, never set the [cut torque] to MC5 or MC6.
Set the [cut torque] exclusively when multiple reels are selected.
*3 : Setting of AI2, AI3
When the control reel is set to the feed reel, never set the[taper ratio]or the[diameter] to AI2 or AI3.
Set the[taper ratio] or the[diameter] exclusively when the control reel is set to[winding] or[unwinding]
When the taper signals set to [external], make sure to set the winding diameter to AI2 or AI3.
When the control reel is set to one reel or the feed reel, never set the [new reel preset] to AI2 or AI3.
Set the [new reel preset] exclusively when multiple reel are selected.
• These inputs are always valid even if set screen is not displayed.
• These analog values are digitized by 12-bit A/D converter.
The monitor data contains the following items, and is not saved if power is interrupted.
• Tension monitor, total( N,x10N)
• Tension, target (N,x10N)
• Tension monitor, left (N,x10N)
Value based on the set tension while taking the
• Tension monitor, right (N,x10N)
decrease ratio of the taper tension into account.
• Control output(0~100%)
• Reel diameter input(min. diameter ~ max. diameter)
Set item
Description
Initial
set
Memory
cassett
transfer
*1
Setting
during
operation
Mainly
refer
page
Sel
e
ct
ion
it
em
Control while stop timer
feed back / Fixed
feed back
c
×
28
Unit of tension
×
10N / N
N
c
×
10
Control reel
Unwinding / Winding / Feed
Unwinding
c
×
11
Number of reels
One reel / Multi reels
One reel
c
×
11
Taper control
OFF / ON
OFF
c
×
31
Taper signal
Internal / External
Internal
c
×
31
Taper mode
Linear / Nonlinear
Linear
c
×
32
Actuator
Powder / Servo
Powder
c
×
11
Stall mode
Key set / MANUAL vol.
MANUAL
c
×
16
Stall reset
MC4 / MC4+OUT SW.
MC4+OUT SW.
c
×
15
AI2/AI3 setting
Diameter / Stall / New reel preset
/ Taper ratio / Ext. tension
Not set
c
×
48
*2
MC5/MC6 setting
Gain 2 / Inching / OUT remote
/ Cut torque
Not set
c
×
48
*3
Number of detectors
2 / 1
2
c
×
12
Automatic gain
Automatic / Manual
Manual
c
×
34
Name
Unit
Digital data for analog value of 0~5V
Increment
Remark
In
terna
l Manual torque
%
0 ~ 100
1
Tension setting
N
0 ~ full scale tension
1
×
10N
0.1
E
xte
rnal
Tension
setting(AI1)
N
0 ~ full scale tension
1
×
10N
0.1
Tension detec-
tor (auxiliary)
N
0 ~ full scale tension
1
Terminals AI2 and AI3
are set by parameters.
×
10N
0.1
Taper ratio
setting
%
0 ~ 80%(0=Set tension):Int.diameter
1
0 ~100%(0=Set tension):Ext.diameter
Stall setting
%
0 ~100%
1
New reel preset
%
0 ~100%
1
Diameter input
mm
φ
min. diameter ~ max. diameterÅÖ2000
11
1. Selection item