11.3 Various settng values
The items indicated with white letters on a black ground must be always set. Another items are set in ac-
cordance with the functinon used.
*1 : These parameter avail setting data copy by using memory cassette.
*2 : The setting of the item marked with "
×
" on the " Setting during operation " column cannot be changed
while the MC input is turned on.
Set items
Set values
Unit
Set range
Initial
value
*1
Memory
cassette
transfer
*2
Setting
during
operation
Mainly
refer
page
Minimum
Maximum
Te
n
si
on
Tension
setting
Tension set value (N)
N
0.1 ,1 or 10 ~ FS tension
–
NG
c
18
Tension set value(
×
10N)
N
0.01 ,0.1 or 1 ~ FS tension
–
NG
c
18
Full scale
tension
Full scale value
–
1
1999
500
c
×
12
Decimal point (N)
–
0.1, 1.0 or 10
×
1
c
×
12
Decimal point (
×
10N)
–
0.01 ,0.1 or 1
×
0.1
c
×
12
Tension
detector
Zero adjustment
–
0
0
0
NG
×
12
Span adjustment
target value
N
1 digit ~ FS tension
(1/3 or more of FS tension)
500
c
×
12
×
10N
50.0
Filter
Display time constant
s
1/4, 1/2, 1, 2,or 4
1/2
c
c
35
TMO output time constant
s
1/2
c
c
42
Zero tension
detection
value
Zero tension (N)
N
0
1999
0
c
×
36
Zero tension (
×
10N)
×
10N
0
199.9
0.0
c
×
36
Manual setting Manual set value
%
0
100
–
c
c
18
Ta
pe
r
Linear
taper
Taper ratio(int. diameter)
%
0
80
0
c
c
31
Taper ratio(ext. diameter)
%
0
100
0
c
c
32
Non-linear
taper
Corner 1~4
mm
φ
0
2000
0
c
c
33
Taper 1~4
%
0
100
0
c
c
33
St
ar
t
Stall
Stall set value
%
0
100
20
c
c
15
Timer
Start timer
s
0.0
10.0
4.0
c
c
28
Output gain
Gain 1
%
5
400
100
c
c
29
Gain 2
%
5
400
100
c
c
29
New reel
/old reel
switch-over
New reel preset value
%
0
100
50
c
c
25
Preset timer
s
0.0
30.0
4.0
c
c
25
Old reel cut torque
%
0
100
10
c
c
38
Stop control
Stop timer
s
0.0
100.0
6.0
c
c
28
Stop gain
%
5
400
100
c
c
28
Stop bias
%
0
50
0
c
c
28
Mechanical loss
correction
Reel
A
Powder mode
%
0
100
0
c
c
37
AC servo mode
%
–50
100
0
c
c
37
Reel
B
Powder mode
%
0
100
0
c
c
37
AC servo mode
%
–50
100
0
c
c
37
Reel diameter
Minimum diameter
mm
φ
0
2000
100
c
×
32
Maximum diameter
mm
φ
Minimum set
diameter
2000 1000
c
×
32
Co
nt
ro
l g
ai
n
Manual
setting
Proportional gain (P gain)
%
0
100
50
c
c
35
Integral time
%
1
100
50
c
c
35
Dead zone gain
%
0
100
–
P gain
0
c
c
35
Dead zone width
%
0
100
50
c
c
35
Automatic
gain setting
Addition torque
%
0
100
20
c
c
34
Password
–
0
32767 4095
×
c
10