![Mitsubishi H2i-R2-1 Manual Download Page 98](http://html1.mh-extra.com/html/mitsubishi/h2i-r2-1/h2i-r2-1_manual_1809275098.webp)
H2i-R2-98
PURY-HP-T(S)KMU,-Y(S)KMU (September 2014)
© 2014 Mitsubishi Electric US, Inc.
7. CAPACITY TABLES
7-4-17. Heating Capacity [High Heat Performance Mode] with PURY-HP72TKMU-A-H (cont.)
6. CAPACITY TABLES
DATA U10
OUTDOOR UNITS
2 - 380
H
2i
R
2
70
-13.0
46300
27000
46300
27700
46300
27800
46400
28100
-9.0
49400
27200
49500
27900
49600
28200
49100
28200
-4.0
53200
27500
53200
28200
52900
28700
47700
25700
1.0
56800
27800
56600
28600
52900
26800
46300
23300
5.0
59600
28000
59000
29000
51900
24900
45200
21500
10.0
62900
28200
59000
26600
50500
22700
43800
19300
14.0
65400
28400
58000
24700
49400
20900
42700
17600
19.0
65200
26100
56800
22400
48000
18600
41300
15500
23.0
63700
24000
55900
20500
46900
16800
40200
13900
28.0
63700
21700
55900
18400
46900
15100
40200
12500
32.0
63700
20200
55900
17100
46900
14000
40200
11600
37.0
63700
18600
55900
15600
46900
12800
40200
10700
41.0
63700
17400
55900
14700
46900
12000
40200
10000
43.0
63700
16800
55900
14400
46900
11600
40200
9800
46.0
63700
16000
55900
13700
46900
11100
40200
9400
50.0
63700
15100
55900
13000
46900
10600
40200
8900
55.0
66300
15200
55900
12300
46900
10200
40200
8500
59.0
69300
15200
55900
11900
46900
10000
40200
8300
60
-13.0
39700
23200
39700
23900
39700
23900
39800
24300
-9.0
42300
23500
42400
24000
42500
24300
42100
24300
-4.0
45600
23700
45600
24300
45300
24700
40900
22200
1.0
48700
23900
48500
24700
45400
23100
39700
20100
5.0
51100
24100
50500
25000
44500
21500
38700
18500
10.0
53900
24300
50600
23000
43300
19500
37500
16600
14.0
56100
24500
49800
21300
42400
18000
36600
15200
19.0
55900
22500
48700
19300
41200
16000
35400
13400
23.0
54600
20700
47900
17700
40200
14500
34500
12000
28.0
54600
18700
47900
15900
40200
13000
34500
10800
32.0
54600
17500
47900
14700
40200
12100
34500
10000
37.0
54600
16000
47900
13500
40200
11000
34500
9200
41.0
54600
15000
47900
12700
40200
10300
34500
8700
43.0
54600
14500
47900
12400
40200
10000
34500
8400
46.0
54600
13800
47900
11800
40200
9600
34500
8100
50.0
54600
13000
47900
11200
40200
9200
34500
7700
55.0
56800
13100
47900
10600
40200
8800
34500
7400
59.0
59400
13100
47900
10300
40200
8600
34500
7200
50
-13.0
33100
19900
33100
20400
33100
20500
33100
20700
-9.0
35300
20000
35400
20600
35400
20800
35100
20700
-4.0
38000
20300
38000
20800
37800
21200
34100
18900
1.0
40600
20500
40400
21100
37800
19700
33100
17200
5.0
42600
20600
42100
21300
37100
18400
32300
15900
10.0
44900
20800
42100
19600
36100
16700
31300
14200
14.0
46700
20900
41500
18200
35300
15400
30500
13000
19.0
46600
19300
40600
16500
34300
13700
29500
11400
23.0
45500
17700
39900
15100
33500
12400
28700
10300
28.0
45500
16000
39900
13600
33500
11100
28700
9200
32.0
45500
14900
39900
12600
33500
10300
28700
8600
37.0
45500
13700
39900
11500
33500
9400
28700
7900
41.0
45500
12800
39900
10900
33500
8800
28700
7400
43.0
45500
12400
39900
10600
33500
8600
28700
7200
46.0
45500
11800
39900
10100
33500
8200
28700
6900
50.0
45500
11100
39900
9600
33500
7800
28700
6600
55.0
47300
11200
39900
9100
33500
7500
28700
6300
59.0
49500
11200
39900
8800
33500
7400
28700
6100
PURY-HP72TKMU-A-H
TC:Total Capacity(BTU), PI:Power Input(BTU)
Combination
Outdoor
Indoor air temp.
(%)
air temp.
59°F D.B.
70°F D.B.
77°F D.B.
81°F D.B.
°F W.B.
TC
PI
TC
PI
TC
PI
TC
PI
kcal/h=kW x 860 , BTU/h = kW x 3,412