PURY-HP-T(S)KMU,-Y(S)KMU (September 2014)
© 2014 Mitsubishi Electric US, Inc.
4. ELECTRICAL WIRING DIAGRAMS
2 - 259
4. ELECTRICAL WIRING DIAGRAMS
DATA U10
OUTDOOR UNITS
H
2i
R
2
4. ELECTRICAL WIRING DIAGRAMS
PURY-HP72, 96TKMU-A-H(-BS)
For opening/closing the bypass circuit
Terminal block
Central control transmission cable
Power supply
Function setting connector
IPM temperature
Heat exchanger outlet pipe temperature
ACC inlet pipe temperature
Discharge pipe temperature
Thermistor
SV9
TB1 TB3 TB7
TH4 TH5 TH6
THHS Z24,25,26
DC reactor
Current sensor(AC)
Low pressure
Discharge pressure
High pressure protection for the outdoor unit
Pressure switch
Pressure sensor
Explanation
Explanation
4-way valve (Cooling/Heating switching)
For opening/closing the bypass circuit under the O/S
Solenoid valve
Solenoid valve
DCL
LEV5a
ACCT1,2
63LS
63HS1
63H1
<Symbol explanation>
Symbol
Symbol
21S4a
C1 DCCT1
SV1a
SV5b
Outdoor unit heat exchanger capacity control
SV4a,b,d
Subcooled liquid refrigerant temperature
*1.
Single-dotted lines indicate wiring not
supplied with the unit.
*2.
Dot-dash lines indicate the control box
boundaries.
*3.
Refer to the Data book for connecting
input/output signal connectors.
*4.
Daisy-chain terminals (TB3) on the outdoor
units in the same refrigerant system together
.
*5.
Faston terminals have a locking function.
Make sure the terminals are securely locked
in place after insertion. Press the tab on
the terminals to removed them.
*6.
Control box houses high-voltage parts.
Before inspecting the inside of the control box,
turn of
f the power
,keep the unit of
f for at
least 10 minutes, and confirm that the voltage
at both ends of the main capacitor (C1) has
dropped to DC20V or less.
X001
For inrush current prevention
R1
Choke coil (for high frequency noise reduction)
L
Indoor/Outdoor transmission cable
Magnetic relay (inverter main circuit)72C
Heat exchanger capacity control
Linear expansion valve (for the control of evaporating temperature)
Resistor
For current detection
RSH01
Capacitor (inverter main circuit) Current sensor(DC)
For opening/closing the injection circuit
LEV4
For opening/closing the defrost circuit
SV10,1
1
OA
temperature
TH7 TH9,1
1
Ground
L3
L2
L1
X14
X13
6
1
3
5
12
red CNPS
1
3
2
1
TP1
TP2
TB3
2
3
TB7
M1
M2
M1
M2
S
5
12
34
1
2
t°
1
2
1
32
3
4
6
1 2
2
CN82 blue
1
3 4
CN83 black
3
1
6
X12
1
3
CN508 blue
CN4 black
2
3
1
t
SW001
1
3
°
CN2
7
12
1
3
3
1
4
3
2
2
3
1
1
TH4
t
4
°
1
1
CN21
1
green
2
3
123
321
6
CNSNR
5 4 3 2 1
U
V
W
Fan motor (Heat exchanger)
MS 3~
4
1
6
CNINV
2
SW1
1
6
OFF
ON
3
2
2
3
Power failure detection circuit
red
1
Surge absorber
2
3
1
TB1
L3
L2
L1
21
INV Board
°t
2
L
yellow CNPOW
t°
654
5
CNVDC
4
CNDC2
1
ACCT2
F02 AC250V 3.15A
T
C1
IPM
4
X10
ON
X08
Unit address setting
LED3:Charge
6
3
1
6
F001 AC250V 6.3A
T
F002 AC250V 6.3A
T
RSH01
CN001
531
TB22
TB23
TB21
Diode stack
~
~~
12
3
4
3
green CN62
CN990 green
CNTYP4
CN201
Z25
1
TH5
2
SWU2
LED1
SW6
10
Control Board
CN40
63HS1
CN41
TH7
1
5
5
4
3
1
SW4
LED3
2
LEV5a
3
SET
UP(SW6-10)
V
M
OFF
CN506 red
yellow CN3K
*3
Compressor ON/OFF output Error detection output
DC12V
CN51
SV5b
W
blue CN3N
1
3
3
4
TB7 Power selecting connector
CNVDC
IPM
5
1
26
ON
OFF
M-NET
power
supply circuit
1
2
M-NET
Board
Power failure detection circuit
Indoor/Outdoor transmission cable
ON
1's digit
CN102
1
4
1
U
10's digit
OFF
LED2:Normal operation(Lit)
/ Error(Blink)
yellow
CNDC red
MS 3~
2
TH6
U
LED1:Power supply to
Indoor/Outdoor transmission line
ZNR400
Central control transmission cable
ON
OFF
Motor
(Compressor)
red CN3S
1
CN04 red
CN43 yellow
CN61 green
CN202
red
8
/ Error(Blink)
*4
2
P
63H1
4
1
SW5
10
5
CN3D
1
CPU power supply circuit
black CNAC2
1
*3
ON
OFF
10
SWU1
N
CN212
red
WU
P
6
CNDC1
1
4
V
1
CN80
25
F301 AC250V 15A
T
CNIPM
CNTYP5 green
LED4:CPU in operation
FT
-N
LED1:Normal operation(Lit)
/ Error(Blink)
CN801 red
SWP1
CN012
1
3
FAN Board
63LS
U
-
+
ZNR005
Z24
2
CN507 black
3
F003 AC250V 6.3A
T
TB42
6
4
X001
CN213 green
black
*5
SV9
Function setting
LED1 Display setting/ Function setting
red
LED4:CPU in operation
5
1
SC-P1
DCL
black
CN72C
red
3
1
DCCT1
1
2
1
4
1
C
N
LVA
1
CNR1 red
black
F01 AC250V 3.15A
T
TB31
R1
white
red
CNIT red
X001
1
2
Power Source
3~ 60Hz 208/230V
CNCT
red
white
ACCT1
5
6
CN1
10
Noise filter
31
6
4
1
2
IPM power supply circuit
CNFG2
Noise Filter
black
4
3
2
1
CNCT2 blue
4
3
2
1
X05
X06
3
5
1
6
CN505
1
3
1
2
CNFG blue
1
2
black
red
white
*5
black
red
THHS
°t
Z26
CNTYP
2
CNTH green
21
CN1
10
black
2 1
red
1
2
1
CNAC
CN81 green
1
2
5
1
3
4
4
SV4a
4
CN2
C310,C31
1
SV4d
SV1a
SV4b
21S4a
1
2
3
4
6
M
CNL
VE
yellow
LEV4
TH9
TH1
1
t°
2
CN509 yellow
CNS2
3
2
3
1
X04
yellow
CN504
SV1
1
3
1
X03
green
CN503
SV10
CN72C
green
LED1:Normal operation(Lit)