![Mitsubishi H2i-R2-1 Manual Download Page 6](http://html1.mh-extra.com/html/mitsubishi/h2i-r2-1/h2i-r2-1_manual_1809275006.webp)
H2i-R2-6
PURY-HP-T(S)KMU,-Y(S)KMU (September 2014)
© 2014 Mitsubishi Electric US, Inc.
1. SPECIFICATIONS
Model
PURY-HP192TSKMU-A-H
Power source
3-phase 3-wire 208 / 230V ±10% 60Hz
Cooling capacity (Nominal) *1 (208 / 230V)
Btu/h
192,000
kW
56.3
Power input
kW
15.86 *4
Current input
A
48.9 / 44.2 *4
Temp. range of cooling *3
Indoor
W.B.
59 ~ 75° F(15 ~ 24° C)
Outdoor
D.B.
23 ~ 115° F (-5 ~ +46° C) *5
Heating capacity (Nominal) *2 (208-230V)
Btu/h
215,000
kW
63.0
Power input
kW
18.52 *4
Current input
A
55.9 / 50.5 *4
Temp. range of heating *3
Indoor
D.B.
59~81°F(15~27°C)
Outdoor
W.B.
-13~60°F(-25~15.5°C)
System Compressor Operating Range
Heating: 6-100%
Indoor unit
connectable
Total capacity
50~150 % of outdoor unit capacity
Model / Quantity
P06~P96 / 1-48
Sound pressure level (measured in anechoic room)
dB <A>
61.0
Refrigerant piping diameter
from Twinning Kit to Indoor
Units
Liquid (High Pressure)
In. (mm)
7/8”(22.2) Brazed
Gas (Low Pressure)
In. (mm)
1-1/8”(28.58) Brazed
Set Model
Model
PURY-HP96TKMU-A-H
PURY-HP96TKMU-A-H
Fan
Type x Quantity
Propeller fan x 1
Propeller fan x 1
Airflow rate
CFM
6,200
6,200
m3 / min
175
175
L/s
2,920
2,920
Control , Driving mechanism
Inverter-control, Brushless DC motor
Inverter-control, Brushless DC motor
External static pressure *6
0 in.WG (0 Pa) *6
0 in.WG (0 Pa) *6
Compressor
Type x Quantity
Inverter scroll hermetic compressor x 1
Inverter scroll hermetic compressor x 1
Manufacturer
AC&R Works, MITSUBISHI ELECTRIC CORP. AC&R Works, MITSUBISHI ELECTRIC CORP.
Starting method
Inverter
Inverter
Lubricant
MEL32
MEL32
External finish
Pre-coated galvanized steel sheet
<MUNSELL 5Y 8/1 or similar>
Pre-coated galvanized steel sheet
<MUNSELL 5Y 8/1 or similar>
External dimension H x W x D
In.
64-31/32 x 48-1/16 x 29-15/16
64-31/32 x 48-1/16 x 29-15/16
mm
1,650 x 1,220 x 760
1,650 x 1,220 x 760
Protection
devices
High pressure protection
High pressure sensor, High pressure switch at
4.15MPa (601 psi)
High pressure sensor, High pressure switch at
4.15MPa (601 psi)
Inverter circuit (COMP. / FAN)
Over-current protection
Over-current protection
Fan Motor
Thermal switch
Thermal switch
Minimum Circuit Ampacity (MCA)
A
60 / 54
60 / 54
Recommended Fuse/Breaker Size
A
65
65
Maximum Fuse Size
A
80
80
Refrigerant
Type x original charge
R410A x 26 lbs + 1oz (11.8kg)
R410A x 26 lbs + 1oz (11.8kg)
Control
LEV and HIC circuit
Net weight
lbs (kg)
552 (250)
552 (250)
Heat exchanger
Salt-resistant cross fin & copper tube
Salt-resistant cross fin & copper tube
Refrigerant piping diameter
from Module to Twinning Kit
Liquid (High Pressure)
In. (mm)
3/4”(19.05)Brazed
3/4”(19.05)Brazed
Gas (Low Pressure)
In. (mm)
7/8”(22.2)Brazed
7/8”(22.2)Brazed
Defrosting method
Auto-defrost mode (Reversed refrigerant cycle)
Drawing
External
KJ94G492
Wiring
KE94C883
KE94C883
Standard attachment
Document
Installation Manual
Accessory
Details refer to External Drw
Optional parts
Outdoor Twinning kit: CMY-Y100CBK2
Joint: CMY-Y102SS-G2,CMY-Y102LS-G2,CMY-Y202S-G2,CMY-R160C-J
Main BC controller: CMB-P108,1010,1013,1016NU-GA,1016NU-HA
Sub BC controller: CMB-P104,108NU-GB,CMB-P1016NU-HB
Remark
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and
other items shall be referred to the Installation Manual.
*3 Harsh weather environments may demand performance enhancing equipment.
Ask your Mitsubishi Electric representative for more details on your region.
*4 For details on the electrical data needed for installing these units,
see the H2i R2-Series System Design section.
*5 For details on extended ambient cooling operation range down to -10°FDB (-23°CDB),
see Low Ambient Cooling Kit information.
*6 External static pressure is adjustable via dipswitch setting
(0.12 in.WG, 0.24 in.WG / 30Pa, 60Pa).
Note:
*1 Nominal cooling conditions
*2 Nominal heating conditions
Unit converter
Indoor:
80degF D.B./ 67degF W.B.
70degF D.B.
kcal =kW x 860
(26.7degC D.B./ 19.4degC W.B.)
(21.1degC D.B.)
BTU/h =kW x 3,412
Outdoor:
95degF D.B. (35degC D.B.)
47degF D.B./ 43degF W.B.
(8.3degC D.B./ 6.1degC W.B.)
cfm =m
3
/min x 35.31
lb =kg / 0.4536
Pipe length:
25ft.(7.6m)
25ft.(7.6m)
* Above specification data is subject to rounding
variation.
Level difference:
0ft.(0m)
0ft.(0m)
* Due to continuing improvement, above specifications may be subject to change without notice.