7. CAPACITY TABLES
7-8-30. Heating Capacity [Intelligent Heat Mode] with PURY-HP96YKMU-A (cont.)
2 - 455
6. CAPACITY TABLES
DATA U10
OUTDOOR UNITS
H
2i
R
2
70
-25.0
16.65
9.04
16.64
9.35
16.65
9.48
15.98
9.24
-22.8
17.77
9.16
17.78
9.44
17.77
9.71
15.98
8.74
-20.0
19.20
9.32
19.20
9.60
18.64
9.65
15.98
8.12
-17.2
20.63
9.48
20.62
9.78
18.64
8.95
15.98
7.54
-15.0
21.75
9.60
21.72
9.95
18.64
8.43
15.98
7.11
-12.2
23.18
9.76
22.19
9.65
18.64
7.81
15.98
6.58
-10.0
22.49
8.75
19.66
7.83
18.64
7.34
15.98
6.19
-7.2
22.19
7.80
18.86
6.85
18.64
6.79
15.98
5.72
-5.0
22.19
7.41
18.86
6.43
18.64
6.38
15.98
5.37
-2.2
24.50
7.92
21.33
6.74
18.64
5.89
15.98
4.95
0.0
25.30
7.90
22.19
6.67
18.64
5.53
15.98
4.65
2.8
25.30
7.27
22.19
6.13
18.64
5.11
15.98
4.29
5.0
25.30
6.81
22.19
5.77
18.64
4.81
15.98
4.04
6.1
25.30
6.59
22.19
5.61
18.64
4.67
15.98
3.91
7.8
25.30
6.27
22.19
5.36
18.64
4.46
15.98
3.73
10.0
25.30
5.88
22.19
5.08
18.64
4.21
15.98
3.52
12.8
26.32
5.92
22.19
4.80
18.64
3.94
15.98
3.27
15.0
27.52
5.95
22.19
4.65
18.64
3.74
15.98
3.10
60
-25.0
14.27
7.63
14.26
7.89
14.27
8.00
13.70
7.80
-22.8
15.23
7.73
15.24
7.97
15.23
8.19
13.70
7.38
-20.0
16.45
7.87
16.46
8.10
15.98
8.14
13.70
6.86
-17.2
17.68
8.00
17.67
8.26
15.98
7.56
13.70
6.36
-15.0
18.64
8.10
18.62
8.40
15.98
7.12
13.70
6.00
-12.2
19.87
8.24
19.02
8.15
15.98
6.59
13.70
5.55
-10.0
19.27
7.38
16.85
6.61
15.98
6.20
13.70
5.22
-7.2
19.02
6.58
16.17
5.78
15.98
5.73
13.70
4.82
-5.0
19.02
6.25
16.17
5.43
15.98
5.38
13.70
4.53
-2.2
20.99
6.68
18.28
5.68
15.98
4.97
13.70
4.18
0.0
21.69
6.67
19.02
5.63
15.98
4.67
13.70
3.93
2.8
21.69
6.13
19.02
5.17
15.98
4.31
13.70
3.62
5.0
21.69
5.74
19.02
4.87
15.98
4.06
13.70
3.41
6.1
21.69
5.56
19.02
4.74
15.98
3.94
13.70
3.30
7.8
21.69
5.29
19.02
4.52
15.98
3.77
13.70
3.15
10.0
21.69
4.96
19.02
4.28
15.98
3.56
13.70
2.97
12.8
22.56
5.00
19.02
4.05
15.98
3.32
13.70
2.76
15.0
23.59
5.02
19.02
3.92
15.98
3.16
13.70
2.62
50
-25.0
11.89
6.39
11.88
6.61
11.89
6.70
11.41
6.53
-22.8
12.69
6.48
12.69
6.67
12.69
6.86
11.41
6.18
-20.0
13.71
6.59
13.72
6.78
13.31
6.82
11.41
5.74
-17.2
14.73
6.70
14.73
6.91
13.31
6.33
11.41
5.33
-15.0
15.53
6.79
15.51
7.04
13.31
5.96
11.41
5.02
-12.2
16.55
6.90
15.85
6.82
13.31
5.52
11.41
4.65
-10.0
16.06
6.18
14.04
5.53
13.31
5.19
11.41
4.37
-7.2
15.85
5.51
13.47
4.84
13.31
4.80
11.41
4.04
-5.0
15.85
5.24
13.47
4.54
13.31
4.51
11.41
3.79
-2.2
17.49
5.60
15.23
4.76
13.31
4.16
11.41
3.50
0.0
18.07
5.58
15.85
4.72
13.31
3.91
11.41
3.29
2.8
18.07
5.14
15.85
4.33
13.31
3.61
11.41
3.03
5.0
18.07
4.81
15.85
4.07
13.31
3.40
11.41
2.85
6.1
18.07
4.66
15.85
3.97
13.31
3.30
11.41
2.77
7.8
18.07
4.43
15.85
3.79
13.31
3.15
11.41
2.64
10.0
18.07
4.16
15.85
3.59
13.31
2.98
11.41
2.49
12.8
18.80
4.19
15.85
3.39
13.31
2.78
11.41
2.31
15.0
19.65
4.20
15.85
3.29
13.31
2.64
11.41
2.19
PURY-HP96YKMU-A
TC:Total Capacity(kW), PI:Power Input(kW)
Combination
Outdoor
Indoor air temp.
(%)
air temp.
15°C D.B.
21.1°C D.B.
25°C D.B.
27.2°C D.B.
°C W.B.
TC
PI
TC
PI
TC
PI
TC
PI
kcal/h=kW x 860 , BTU/h = kW x 3,412