PURY-HP-T(S)KMU,-Y(S)KMU (September 2014)
H2i-R2-11
© 2014 Mitsubishi Electric US, Inc.
2. EXTERNAL DIMENSIONS
2. EXTERNAL DIMENSIONS
DATA U10
OUTDOOR UNITS
2 - 252
H
2i
R
2
2. EXTERNAL DIMENSIONS
PURY-HP72, 96TKMU-A-H(-BS)
Unit : mm(in)
Refrigerant service valve <High pressure>
Refrigerant service valve <Low pressure>
Refrigerant service valve <Low pressure> Refrigerant service valve <High pressure>
(5-3/4)
(5-3/4)
(1-3/16)
(1-3/16)
(Mounting pitch)
(26-23/32~26-15/16)
(26-13/16)
(Mounting pitch)
(3-5/32)
(3-5/32)
(4-25/32)
(8-9/16) 217
(5-23/32) 145
(10-11/32)
(7-23/32)
(3-5/16)
(3-23/32)
(10-23/32) 272
(1
1-7/8) 301
(8-15/16) 227
(2-1/4)
(2-1/4)
(13/16)
(13/16)
(3-17/32)
(3-1/16)
1
(9-29/32) 251
(9-5/16) 236
(10-23/32) 272
(11-15/16)
(25/32)
(25/32)
(2-25/32)
=(5-29/32)X4
(23-5/8)
<Snow hood attachment hole>
4X5-ø4.6(3/16) Hole (Make hole at the plastic fan guard for snow hood attachment)
Intake air
Discharge air
Control box
Intake air
Service panel
Intake air
<Sling hole>
3
6
2
4
5
8
2X2-14(9/16)X20(13/16) Oval hole
2X2-80(3-5/32)X35(1-13/32) Oval hole
7
*1
Use the pipe joint(field supply) and connect to the refrigerant service
valve piping.
High pressure
ø25.4 (1)
Low pressure
Service valve
Refrigerant pipe
Diameter
High pressure
Low pressure
Model
PUR
Y-HP72TKMU-A-H(-BS)
ø25.4 (1)
ø19.05 Brazed
ø15.88 Brazed
ø45 Knockout hole
Specifications
ø43.7 or ø22.2 Knockout hole
ø62.7 or ø34.5 Knockout hole
Front through hole
Bottom through hole
Bottom through hole
Front through hole
Front through hole
For wires
Usage
Front through hole
Front through hole (Uses when twinning kit (optional parts) is mounted.)
140 × 77 Knockout hole
150 × 94 Knockout hole
Bottom through hole
For pipes
ø52 Knockout hole
For transmission cables
ø34 Knockout hole
ø65 Knockout hole
PUR
Y-HP96TKMU-A-H(-BS)
ø19.05 Brazed
ø25.4
ø25.4
ø22.2 Brazed
58(2-5/16)
75(2-31/32)
146
146
83 (3-9/32)
262
(740)(29-5/32)
150 (5-29/32)
57
54(2-5/32)
19.5
80
1060(41-3/4)
586(23-3/32)
19.5
57
94
84
121
600=150×4
20
1220(48-1/16)
150 (5-29/32)
1650(64-31/32)
196
1347(53-1/16)
89
303
20
740(29-5/32)
70
1181(46-1/2)
140(5-17/32)
80
77
681(678~684)
29.5
29.5
Bottom view
Left side view
Front view
Top view
Note1.
Please refer to the next page for information
regarding necessary spacing around the
unit and foundation work.
2.
At brazing of pipes,wrap the refrigerant service valve
with wet cloth and keep the temperature of
refrigerant service valve under 120°C(248°F).
Connecting pipe specifications
(3/4)
*1
(5/8)
*1
(1-25/32)
(2-9/16)
(1-3/4)
(2-15/32) (1-3/8)
(7/8)
(1-1
1/32)
(2-1/16)
(5-29/32) (3-23/32)
(5-17/32) (3-1/16)
(3/4)
*1
(1)
(1)
(7/8)
*1
NO.
1
2
3
4
5
6
7
8