FX2N-64CL-M CC-Link/LT Master Block
Connection of Cables, Connectors and Terminating Resistors 6
6-7
•
When the VCTF cable/high flexible cable is used as the trunk line
Trunk line, Drop line: VCTF cable, High flexible cable
After striping the sheath by 70mm (2.75”) or more, perform the procedure for the
dedicated flat cable in the same way as the T-branch.
Set the cover to the position
in which T-branch will be.
Execute press-fitting in the
same way as steps and
of the attachment procedure.
Cut at the root of the tip of
the cover with nippers, etc.,
and remove the tip.
Cut off here.
22.5mm
(0.88")
VCTF cable/
High flexible cable
(drop line)
VCTF cable/
High flexible cable
connector
VCTF cable/High flexible cable
(trunk line)
VCTF cable/
High flexible cable
connector