36
Communi-
cation
Parameter
Indica-
tion
Name
Outline
Factory
Setting
<NA, EC
Version>
n11
(341)
CR/LF selection
0: Without CR/LF
1: With CR, without LF
2: With CR/LF
1
n12
(342)
E
2
PROM write
selection
0: Write to RAM and E
2
PROM
1: Write to RAM only
0
n13
(145)
PU display
language
0: Japanese
1: English
2: German
3: French
4: Spanish
5: Italian
6: Swedish
7: Finish
0
<1>
n14
(990)
PU buzzer sound
control
0: Without sound, 1: With sound
1
n15
(991)
PU contrast
adjustment
0 (bright)
63 (dark)
58
n16
(992)
PU main display
screen data
selection
0: Selectable between output frequency and
output current
100: Set frequency (during stop)
Output frequency (during operation)
0
n17
(993)
PU disconnection
detection/PU
setting lock
0: Without PU disconnection error/PU
operation valid
1: Error at PU disconnection/PU operation valid
10: Without PU disconnection error/
PU operation invalid
0
For details of the program, etc., refer to the instruction manual (detailed)