25
6.
FUNCTION LIST
6.1 Basic Function Parameter List
Pa-
rame-
ter
Name
Indica-
tion
Setting
Range
Minimum
Setting
Increments
Factory
Setting
<EC Version>
Customer
Setting
0
Torque boost
0 to 15%
0.1%
6%
1
Maximum frequency
0 to 120Hz
0.1Hz
60Hz <50Hz>
2
Minimum frequency
0 to 120Hz
0.1Hz
0Hz
3
Base frequency
0 to 120Hz
0.1Hz
60Hz <50Hz>
4
Multi-speed setting
(high speed)
0 to 120Hz
0.1Hz
60Hz <50Hz>
5
Multi-speed setting
(middle speed)
0 to 120Hz
0.1Hz
30Hz
6
Multi-speed setting
(low speed)
0 to 120Hz
0.1Hz
10Hz
7
Acceleration time
0 to 999s
0.1s
5s
8
Deceleration time
0 to 999s
0.1s
5s
9
Electronic thermal
O/L relay
0 to 50A
0.1A
Rated output
current
30
Extended function
display selection
0, 1
1
0
79
Operation mode
selection
0 to 4, 7, 8
1
0
Remarks
•
The extended function parameters are made valid by setting "1" in Pr. 30
"extended function display selection". (Refer to page 18)
•
The decimal places of a value of 100 or more (3 digits or more) cannot be set
to be displayed.
6.2 Explanation of the Basic Function Parameters
For details, refer to the instruction manual (detailed) separately available.
Pr. 0 "torque boost"
Pr. 1 "maximum frequency",
Pr. 2 "minimum frequency"
•
Clamp the upper and lower limits of
the output frequency.
Pr.1
Pr.2
Frequency
settin
Minimum
frequency
Maximum
frequency
Out
put
f
requ
en
c
y
5V
(10V)
(20mA) etc.
•
Allows the motor torque in the low
speed range to be adjusted
according to the load.
Make adjustment when stall
prevention is operated when starting.
•
When a constant-torque motor is
used, set the following value:
•
0.1K to 0.75K ......6%
•
1.5K to 3.7K ........4%
Setting
range
Base
frequency
0
100%
Output
frequency
Pr.0
Pr.3
Out
put
v
o
lta
g
e