18
4.2.2 Example: Changing the Pr. 30 setting from "0" to "1"
(The extended parameters are made valid by setting "1" in Pr. 30 "extended
function display selection". Refer to page 27 for the extended function parameter
list and to the instruction manual (detailed) for details.)
After parameter setting is complete, press the key once to show the alarm
history or twice to return to the monitor display. To change the setting of another
parameter, perform the operation in above steps 3 to 6.
1.
2.
MODE
Press the key to choose the
parameter setting mode.
MODE
SET
SET
3.
5.
4.
SET
6.
Press the key to set the value.
SET
MODE
RUN
PU
EXT
Flicker ... Parameter setting complete!!
Turn the setting dial to change
it to the set value of .
By turning the setting dial , you can read another parameter.
SET
Press the key to show the setting again.
SET
Press the key twice to show the next parameter.
Press the key to read the
currently set value.
(factory setting) appears.
Confirm the RUN indication and operation
mode indication.
The inverter must be at a stop.
The inverter must be in the PU operation
mode. (Press the key.)
PU
EXT
Operation
Display
" "
" "
The parameter
number read
previously
appears.
Turn the setting dial until
(Pr. 30) appears.
Error display?
•
If the operation panel does not have the write precedence (only for
the type with RS-485 communication function)
•
If write was performed during operation
•
If write was performed in the external operation mode
Remarks
If the setting has not been changed, the value does not flicker and the next
parameter number appears.