C16
(919)
Terminal 1 bias command
(torque/magnetic flux)
0.1%
0%
0 to 400%
Set the torque/magnetic flux command value on the
bias side of terminal 1 input. (valid when
Pr. 868
≠
0,
5)
C17
(919)
Terminal 1 bias (torque/
magnetic flux)
0.1%
0%
0 to 300%
Set the converted % of the bias side voltage
(current) of terminal 1 input. (valid when
Pr. 868
≠
0,
5)
C18
(920)
Terminal 1 gain command
(torque/magnetic flux)
0.1%
150%
0 to 400%
Set the torque/magnetic flux command value on the
gain side of terminal 1 input. (valid when
Pr. 868
≠
0,
5)
C19
(920)
Terminal 1 gain (torque/
magnetic flux)
0.1%
100%
0 to 300%
Set the converted % of the gain side voltage
(current) of terminal 1 input. (valid when
Pr. 868
≠
0,
5)
C38
(932)
Terminal 4 bias command
(torque/magnetic flux)
0.1%
0%
0 to 400%
Set the torque/magnetic flux command value on the
bias side of terminal 4 input. (valid when
Pr. 858
=
1,
4)
C39
(932)
Terminal 4 bias (torque/
magnetic flux)
0.1%
20%
0 to 300%
Set the converted % of the bias side current (voltage)
of terminal 4 input. (valid when
Pr. 858
= 1, 4)
C40
(933)
Terminal 4 gain command
(torque/magnetic flux)
0.1%
150%
0 to 400%
Set the torque/magnetic flux command value on the
bias side of terminal 4 input. (valid when
Pr. 858
=
1,
4)
C41
(933)
Terminal 4 gain (torque/
magnetic flux)
0.1%
100%
0 to 300%
Set the converted % of the gain side current (voltage)
of terminal 4 input. (valid when
Pr. 858
= 1, 4)
—
989
Parameter for manufacturer setting. Do not set.
Buz
zer cont
rol
of
t
he
operat
ion
panel
990
PU buzzer control
1
1
0
Without buzzer
1
With buzzer
P
U
co
nt
ras
t
adjust
ment
991
PU contrast adjustment
1
58
0 to 63
Contrast adjustment of the LCD of the parameter unit
(FR-PU04/FR-PU07) can be performed.
0 (Light)
→
63 (Dark)
Pa
ra
met
e
r cl
ea
r,
pa
ra
me
te
r c
o
py
Pr.CL
Parameter clear
1
0
0, 1
Setting "1" returns all parameters except calibration
parameters to the initial values.
ALLC
All parameter clear
1
0
0, 1
Setting "1" returns all parameters to the initial values.
Er.CL
Faults history clear
1
0
0, 1
Setting "1" will clear eight past faults.
PCPY
Parameter copy
1
0
0
Cancel
1
Read the source parameters to the operation panel.
2
Write the parameters copied to the operation panel to
the destination inverter.
3
Verify parameters in the inverter and operation panel.
The parameter number in parentheses is the one for use with the parameter unit (FR-PU04/FR-PU07).
Func
tio
n
Parameter
Name
Incre
ments
Initial
Value
Range
Description
Re
la
te
d
p
ara
m
e
te
rs