112
Aut
o
mat
ic ac
celerat
io
n
/dec
el
er
at
ion
61
Reference current
0.01A
9999
0 to 500A
Setting value (rated motor current) is referenced
9999
Rated inverter current is referenced
62
Reference value at
acceleration
0.1%
9999
0 to 220%
Setting value is a limit
value
Shortest acceleration/
deceleration mode
Setting value is an
optimum value
Optimum acceleration/
deceleration mode
9999
150% is a limit value
Shortest acceleration/
deceleration mode
100% is an optimum value
Optimum acceleration/
deceleration mode
63
Reference value at
deceleration
0.1%
9999
0 to 220%
Setting value is a limit
value
Shortest acceleration/
deceleration mode
Setting value is an
optimum value
Optimum acceleration/
deceleration mode
9999
150% is a limit value
Shortest acceleration/
deceleration mode
100% is an optimum value
Optimum acceleration/
deceleration mode
64
Starting frequency for
elevator mode
0.01Hz
9999
0 to 10Hz
0 to 10Hz are starting frequency
9999
2Hz is starting frequency
292
Automatic acceleration/
deceleration
1
0
0
Normal mode
3
Optimum acceleration/deceleration mode
5
Elevator mode 1
6
Elevator mode 2
7
Brake sequence mode 1
8
Brake sequence mode 2
11
Shortest acceleration/deceleration mode
293
Acceleration/deceleration
separate selection
1
0
0
Calculate acceleration/deceleration time of both
acceleration and deceleration for the shortest and
optimum acceleration/deceleration mode.
1
Calculate only acceleration time for the shortest and
optimum acceleration/deceleration mode
2
Calculate only deceleration time for the shortest and
optimum acceleration/deceleration mode
Ret
ry f
unc
tion at
alarm
oc
curr
ence
65
Retry selection
1
0
0 to 5
A fault for retry can be selected.
67
Number of retries at fault
occurrence
1
0
0
No retry function
1 to 10
Set the number of retries at fault occurrence. A fault
output is not provided during retry operation.
101 to 110
Set the number of retries at fault occurrence. (The
setting value -100 is the number of retries.) A fault
output is provided during retry operation.
68
Retry waiting time
0.1s
1s
0 to 10s
Set the waiting time from when an inverter fault
occurs until a retry is made.
69
Retry count display erase
1
0
0
Clears the number of restarts succeeded by retry.
—
66
Refer to
Pr. 22 and Pr. 23
.
67 to 69
Refer to
Pr. 65
.
Func
tio
n
Parameter
Name
Incre
ments
Initial
Value
Range
Description
Re
la
te
d
p
ara
m
e
te
rs