![Mitsubishi CP800E Operation Manual Download Page 47](http://html1.mh-extra.com/html/mitsubishi/cp800e/cp800e_operation-manual_1809310047.webp)
45
CONNECTIONS
PRINTING
PRECAUTIONS
FEA
TURES
PREP
ARA
TION
OTHERS
TROUBLE-
SHOOTING
ADJUSTMENTS
ADJUSTMENTS & SETTINGS (SERVICE MENU)
SERVICE MENU ITEMS
KEY SET
Selects the functions of the buttons and function of remote
terminal.
SIGNAL SET1
Sets even/odd number of FIELD, adjusts display, input signals etc.
SIGNAL SET2
Sets sync. signal, signal timing.
PRINT SET
Selects printing direction, paper cutting position, and auto cut.
SYSTEM SET
Page increment, switches outputs of input signal
REMOTE SET
Selects baud rate and RS-232C switches response command, and
selects remote signal.
PREVIOUS ERROR Shows error history.
PRG ALL INIT
Initializes the settings.
CHANGE : OK/CANCEL/INIT
Saves, cancels or initializes the setting of the above functions.
OPERATING SERVICE MENU
1
1
1
1
1
With the power of the unit turned off, press POWER button while
pressing MEMORY button to display SERVICE MENU on the
monitor.
Keep pressing the buttons until the menu is displayed. The time to display the menu
depends on the memorized setting level.
2
2
2
2
2
Select your desired item by pressing
{
{
{
{
{
or
}
}
}
}
}
on the remote
control.
3
3
3
3
3
Press
]
]
]
]
]
button to open a sub menu.
4
4
4
4
4
Select an item you wish to adjust by pressing
{
{
{
{
{
or
}
}
}
}
}
.
5
5
5
5
5
Press
[
[
[
[
[
or
]
]
]
]
]
button to select an item or change value.
6
6
6
6
6
Press SET button.
“ SAVE : OK/CANCEL/INIT” will be selected.
7
7
7
7
7
Press
[
[
[
[
[
or
]
]
]
]
]
button to select OK, CANCEL or INIT.
OK
Saves the setting and exits to the MENU display.
CANCEL
Cancels the setting and exits to the MENU display.
INIT
Initializes all the settings of SERVICE MAIN MENU and
exits the MENU display.
8
8
8
8
8
Select OK and press SET button.
The setting is saved and the normal display is shown.
SERVICE MENU
KEY SETTING
: PUSH [
]
]
SIGNAL SET1
: PUSH [
]
]
SIGNAL SET2
: PUSH [
]
]
PRINT SET
: PUSH [
]
]
SYSTEM SET
: PUSH [
]
]
REMOTE SET
: PUSH [
]
]
PREVIOUS ERROR
: PUSH [
]
]
PRG ALL INIT
:O F F / O N
SAVE : OK/CANCEL/INIT
OPEN
POWER
REMOTE
MEMORY
MONITOR
CP800
MENU
CLEAR
STOP
SET
PRINT
Q' ty
(EXAMPLE) Selecting KEY SET display
KEY SET
KEY LOCK
: OFF/ON
MEM & PRN
: OFF/ON/R1/R2
MEM & STOP : OFF/ON
MEM & MONI : OFF/ON
PRN & CLR
: OFF/PRN/MEM
CLEAR KEY
: MLT/PAGE/ALL
KEEP MONI
: OFF/ON
CHANGE : OK/CANCEL
SERVICE MENU
KEY SETTING
: PUSH [
]
]
SIGNAL SET1
: PUSH [
]
]
SIGNAL SET2
: PUSH [
]
]
PRINT SET
: PUSH [
]
]
SYSTEM SET
: PUSH [
]
]
REMOTE SET
: PUSH [
]
]
PREVIOUS ERROR
: PUSH [
]
]
PRG ALL INIT
:O F F / O N
SAVE : OK/CANCEL/INIT