![Mitsubishi CP800E Operation Manual Download Page 31](http://html1.mh-extra.com/html/mitsubishi/cp800e/cp800e_operation-manual_1809310031.webp)
29
CONNECTIONS
PRINTING
ADJUSTMENTS
PRECAUTIONS
FEA
TURES
PREP
ARA
TION
OTHERS
TROUBLE-
SHOOTING
EXTERNAL REMOTE TERMINAL 1
The image can be stored in memory by sending the remote signal through the external
remote terminal on the rear panel. When the MEM&PRN(MEMORY & PRINT) function
is set to ON, the image will be printed after being stored in memory.
•
Make out the necessary circuit to use this function by referring to the following.
2
2
2
2
2
EXTERNAL REMOTE TERMINAL SIGNAL ALLOCATION (STEREO
JACK)
Pin No.
Function
Description
1
Ground
Earth
2
MEMORY
Memory : When the signal becomes “LOW” from “HIGH”, the
image is stored in memory. (When the signal has
been “LOW” for 60msec. or more, the image is
stored in memory.
3
BUSY
HIGH :
The VCP cannot accept the remote signal.
LOW :
The VCP can accept the remote signal.
• This signal becomes “HIGH” in the following cases;
• During initialization after the VCP has been switched on
• For about 1 sec. after the INPUT SELECT switch has been
set
• During displaying the menu screen
• When the image cannot be stored in memory( BUSY MODE
:MEM)
• If BUSY LEVEL of SYSTEM SET menu is set to L, the above HIGH
and LOW setting gets to be reversed.
•
When the signal from BUSY terminal is received with TTL level, keep the following.
| 1
OL
| = 2mA or less, | 1
OH
| = 1mA or less
| 1
OL
| means the current flowing into the unit at Low output, | 1
OH
| means the
current flowing out of the unit at High output.
2
2
2
2
2
SYNCHRONOUS SETTING FOR MEMORY, BUSY TIMING
BUSY MODE : PRN or MEM, V SYNC MEM : ON in REMOTE SET of SERVICE MENU
1
2
3
1
3
2
Circuit inside and pin No.
Plug pin No.
The numbers in the above figures are just references. The timing may be different
according to the setting.
BUSY MODE : TIM, BUSY TIMING : 1V in REMOTE SET of SERVICE MENU
V SYNC
MEMORY
Image memorizing
a
0
≤
a
≤
7.5msec.
V SYNC
BUSY OUTPUT
Image memorizing
a
a = approx.820
µ
sec.
b
b = approx.660
µ
sec.
BUSY MODE : TIM, BUSY TIMING : 2V in REMOTE SET of SERVICE MENU
V SYNC
BUSY OUTPUT
Image memorizing