![Mitsubishi CP800E Operation Manual Download Page 32](http://html1.mh-extra.com/html/mitsubishi/cp800e/cp800e_operation-manual_1809310032.webp)
30
EXTERNAL REMOTE TERMINAL 2
The image can be stored in memory and printed by sending the remote signal through
the external remote terminal on the rear panel.
•
Make out the necessary circuit to use this function by referring to the following.
2
2
2
2
2
EXTERNAL REMOTE TERMINAL SIGNAL ALLOCATION (MINI
DIN8PIN)
Pin No.
Function
Description
1
Ground
Earth
2
MEMORY
Memory : When the signal becomes “LOW” from “HIGH”, the
image is stored in memory. (When the signal has
been “LOW” for 60msec. or more, the image is
stored in memory.
3
Unused
4
BUSY
HIGH :
The VCP cannot accept the remote signal.
LOW :
The VCP can accept the remote signal.
• This signal becomes “HIGH” in the following cases;
• During initialization after the VCP has been switched on
• For about 1 sec. after the INPUT SELECT switch has been
set
• During displaying the menu screen
• When the image cannot be stored in memory( BUSY MODE
:MEM)
• If BUSY LEVEL of SYSTEM SET menu is set to L, the above HIGH
and LOW setting gets to be reversed.
5
When the signal becomes “LOW” from “HIGH”, the image is
stored in memory. (When the signal has been “LOW” for
60msec. or more, the image is stored in memory.
6
REMOTE
The same functions as the supplied remote control can be
controlled.
7
Unused
8
DC3V
Power supply for the remote control DC 1mA Max.
•
When the signal from BUSY terminal is received with TTL level, keep the following.
| 1
OL
| = 2mA or less, | 1
OH
| = 1mA or less
| 1
OL
| means the current flowing into the unit at Low output, | 1
OH
| means the
current flowing out of the unit at High output.
PRINTING (SPECIAL)
22K
Ω
22K
Ω
10K
Ω
100
Ω
DTC124EK
DC5V
22K
Ω
22K
Ω
10K
Ω
100
Ω
DTC124EK
DC5V
1K
22K
Ω
2.2K
Ω
100
Ω
DTC124EK
DC5V
22K
Ω
To VCP
From VCP
From VCP
To VCP
2
6
4
Circuit inside the VCP
5
MEMORY
BUSY
REMOTE
5
2
1
4
3
6 7 8