![Mitsubishi AJ65SBT-62DA User Manual Download Page 35](http://html1.mh-extra.com/html/mitsubishi/aj65sbt-62da/aj65sbt-62da_user-manual_1809306035.webp)
4 - 3
MELSEC-A
4 SETUP AND PREPARATION BEFORE OPERAATION
4.3 Name of Each Part
The name of each part in the AJ65SBT-62DA is shown.
DA
DG
1
3
5
7
24G
DB
SLD
2
4
6
(FG)
+24V
NC
NC
NC
9
11
13
15
17
19
21
23
25
8
10
12
14
16
18
20
22
24
TEST
NC
TEST
COM
NC
V+
I+
NC
V+
I+
NC
NC
NC
COM
NC
2-piece
(CC-Link
communication
section)
Direct-coupled
(Analog I/O section)
Terminal numbers and signal names
PW
RUN L RUN L ERR.
CH1 2
OFFSET GAIN
MITSUBISHI
A
J65SBT-62DA
DA DG +24V
24G
DB
SLD
(FG)
TEST
TEST NC
V+
I+
NC NC
COM NC
NC COM NC
NC NC
V+
I+
NC
NC
CH1
CH2
SELECT
SET
UP
DOWN
STATION NO.
B RATE
40 20 10 8 4 2 1 4 2 1
ON
MELSEC
1)
2)
3) 4)
5)
6)
7)
8)
Number
Name and
appearance
Description
PW LED
ON: Power supply on
OFF: Power supply off
Normal mode
On
: Normal operation
Flashing : 0.1s intervals indicate an output range setting error.
0.5s intervals indicate a digital value setting error.
Off
: 24VDC power supply shutoff or watchdog timer error
occurred.
RUN LED
Test mode
On
: Indicates that the SELECT/SET switch is in the SET
position.
Flashing : 0.1s intervals indicate that the output range setting is
not any of "user range settings 1 to 3".
0.5s intervals indicate that you attempted to make
offset/gain setting outside the setting range.
Off
: Indicates that the SELECT/SET switch is in the
SELECT or center position.
L RUN LED
On
: Normal communication
Off
: Communication cutoff (time expiration error)
1)
Operation status
display LED
L ERR. LED
On
: Indicates that transmission speed setting or station number setting is
outside the range.
Flicker at fixed intervals
: Indicates that transmission speed setting or station
number setting was changed from that at power-on.
Flicker at unfixed intervals : Indicates that you forgot fitting the termination resistor or
the module or CC-Link dedicated cable is affected by
noise.
Off
: Indicates normal communications.
Normal mode
Normally OFF.
2)
Offset/gain
adjusting LEDs
CH
OFFSET
GAIN
Test mode
The LEDs lit change every time the SELECT/SET switch is moved
to SELECT. (Refer to Section 4.4.)
3)
SELECT/SET
switch
Used to make offset/gain setting in the test mode.
Summary of Contents for AJ65SBT-62DA
Page 2: ......
Page 12: ...A 10 MEMO...
Page 14: ...1 2 MELSEC A 1 OVERVIEW MEMO...
Page 42: ...4 10 MELSEC A 4 SETUP AND PREPARATION BEFORE OPERAATION MEMO...
Page 48: ...5 6 MELSEC A 5 PROGRAMMING 3 Program example...
Page 62: ...6 6 MELSEC A 6 TROUBLESHOOTING MEMO...
Page 69: ...Index 3 MEMO...
Page 71: ......