187
-
'10 • SR-T-091
'09•SRK-DB-087D
(e) Room temperature sensor, indoor heat exchanger sensor, outdoor air temperature sensor, outdoor heat
exchanger sensor table
Units: °C
Buzzer sound
TIMER light
(1’s digit)
RUN light
(10’s digit)
Yes
(sounds for 0.1 second)
6
5
4
3
2
1
0
0
1
2
3
4
5
6
7
8
9
-60
-50
-40
-30
-20
-10
0
10
20
30
40
50
60
70
80
90
0
1
2
3
4
5
6
7
8
9
-61
-51
-41
-31
-21
-11
-1
1
11
21
31
41
51
61
71
81
91
-62
-52
-42
-32
-22
-12
-2
2
12
22
32
42
52
62
72
82
92
-63
-53
-43
-33
-23
-13
-3
3
13
23
33
43
53
63
73
83
93
-64
-54
-44
-34
-24
-14
-4
4
14
24
34
44
54
64
74
84
94
-55
-45
-35
-25
-15
-5
5
15
25
35
45
55
65
75
85
95
-56
-46
-36
-26
-16
-6
6
16
26
36
46
56
66
76
86
96
-57
-47
-37
-27
-17
-7
7
17
27
37
47
57
67
77
87
97
-58
-48
-38
-28
-18
-8
8
18
28
38
48
58
68
78
88
98
-59
-49
-39
-29
-19
-9
9
19
29
39
49
59
69
79
89
99
No
(does not sound)
,IQRGDWDDUHUHFRUGHGHUURUFRGHLVQRUPDOWKHGLVSOD\IRUHDFKVHQVRUEHFRPHVDVVKRZQEHORZ
Sensor name
Room temperature sensor
Indoor heat exchanger sensor
Outdoor air temperature sensor
Outdoor heat exchanger sensor
-64ºC
-64ºC
-64ºC
-64ºC
Sensor value displayed when the error code is normal
([DPSOH5RRPWHPSHUDWXUHLQGRRUKHDWH[FKDQJHURXWGRRUDLUWHPSHUDWXUHRXWGRRUKHDWH[FKDQJHU³&´
0.5 sec.
0.1 sec.
1.5 sec.
Buzzer sound
If the temperature is < 0, the buzzer sounds.
If the temperature is
≧
0, the buzzer does not sound.
11-second interval
0.5 sec.
OFF
ON
OFF
ON
OFF
ON
RUN light
(10’s digit)
TIMER light
(1’s digit)
'09•SRK-DB-087D
(f) Discharge pipe sensor table
Units: °C
Buzzer sound
TIMER light
(1’s digit)
RUN light
(10’s digit)
Yes
(sounds for 0.1 second)
3
2
1
0
0
1
2
3
4
5
6
7
-60
-40
-20
0
20
40
60
80
100
120
140
0
1
2
3
4
5
6
7
8
9
-62
-42
-22
-2
2
22
42
62
82
102
122
142
-64
-44
-24
-4
4
24
44
64
84
104
124
144
-46
-26
-6
6
26
46
66
86
106
126
146
-48
-28
-8
8
28
48
68
88
108
128
148
-50
-30
-10
10
30
50
70
90
110
130
150
-52
-32
-12
12
32
52
72
92
112
132
-54
-34
-14
14
34
54
74
94
114
134
-56
-36
-16
16
36
56
76
96
116
136
-58
-38
-18
18
38
58
78
98
118
138
No
(does not sound)
,IQRGDWDDUHUHFRUGHGHUURUFRGHLVQRUPDOWKHGLVSOD\IRUHDFKVHQVRUEHFRPHVDVVKRZQEHORZ
Sensor value displayed when the error code is normal
-64ºC
([DPSOH'LVFKDUJHSLSHWHPSHUDWXUH³&´
,QWKHFDVHRIGLVFKDUJHSLSHGDWDPXOWLSO\WKHUHDGLQJYDOXHE\%HORZ[ ³&´
0.5 sec.
0.1 sec.
1.5 sec.
11-second interval
0.5 sec.
OFF
ON
OFF
ON
OFF
ON
Buzzer sound
If the temperature is < 0, the buzzer sounds.
If the temperature is
≧
0, the buzzer does not sound.
RUN light
(10’s digit)
TIMER light
(1’s digit)
Summary of Contents for SRK60ZJX-S
Page 85: ... 84 10 SR T 091 4 Ceiling cassette 4way compact type FDTC ...
Page 89: ... 88 10 SR T 091 a PJA012D783 ...
Page 189: ... 188 10 SR T 091 09 SRK DB 087D Service data record form 182 ...
Page 267: ... 266 10 SR T 091 12 5 Super link E board SC ADNA E F SL2NA E and SL3N AE BE to control ...
Page 268: ... 267 10 SR T 091 ...