7 - 14 7 - 14
MELSEC-Q
7 PROGRAMMING FOR EXECUTING THE MASTER FUNCTION
(e) [4. Confirm Auto-Configured Parameters.]
Clicking the Param. Check button on the [Monitor/Test] screen will display
the [4. Confirm Auto-Configured Parameters.] screen.
1)
2)
3)
4)
1) Check the parameters for master function.
Check that the settings such as node No., connection type, and I/O
points are correct. (For the setting details, refer to Section 7.3 (1).)
2) Correct values if any incorrect setting is identified.
Select a value in a Setting value field Execute test button
Repeat this if more than one value must be corrected.
3) To start I/O communication automatically at power-up, set "Start" for
"Auto Communication Start Setting".
Select "Start" Execute test button
4) Click the Close button.