7 - 5 7 - 5
MELSEC-Q
7 PROGRAMMING FOR EXECUTING THE MASTER FUNCTION
(b) Settings of the slave nodes
For the setting of node No. and communication speed, refer to the manual
for each slave node.
1) 1st slave node
(Omron’s CompoBus/D, 8-point input (DRT1-ID08))
Item Setting
Node No.
Node No.1
Communication speed
125kbaud
Connection type
Polling
I/O points
8 input points
2) 2nd slave node
(Omron’s CompoBus/D, 8-point output (DRT1-OD08))
Item Setting
Node No.
Node No.2
Communication speed
125kbaud
Connection type
Polling
I/O points
8 output points
3) 3rd slave node (QJ71DN91(slave node))
Item Setting
Node number (Node number switches)
Node No.4 (04)
Communication speed (Mode switch)
125kbaud (Mode 3)
Connection type
Polling
Slave function receive-bytes (input points)
8 bytes
Slave function transmit-bytes (output points)
8 bytes
4) 4th slave node
(Rockwell Automation’s Flex I/O DeviceNet a 16-point input
(1 IB16))
Item Setting
Node No.
Node No.3
Communication speed
125kbaud
Connection type
Bit strobe
I/O points
16 input points
Summary of Contents for QJ71DN91