45
●
Refrigerant pipe diameter is different according to indoor unit to be connected. When using extention pipes,refer to the tables
below.
●
When diameter of refrigerant pipe is different from that of outdoor unit union, use optional Different-diameter pipe. For further
information on Different-diameter pipe,see page BACK COVER.
Indoor unit
Extention pipe diameter
class
Pipe diameter
Liquid
6.35(1/4)
Liquid
6.35(1/4)
07/09
Gas
9.52(3/8)
Gas
9.52(3/8)
Liquid
6.35(1/4)
Liquid
6.35(1/4)
12(13)
Gas
12.7(1/2)
Gas
12.7(1/2)
Liquid
6.35(1/4)
Liquid
6.35(1/4)
18
Gas
15.88(5/8)
Gas
15.88(5/8)
Outdoor unit union diameter
For
Liquid
6.35(1/4)
Indoor unit A
Gas
12.7(1/2)
Liquid
6.35(1/4)
Indoor unit B
Gas
12.7(1/2)
Liquid
6.35(1/4)
Indoor unit C
Gas
9.52(3/8)
Liquid
6.35(1/4)
Indoor unit D
Gas
9.52(3/8)
Unit : mm (inch)
PIPE SIZE SELECTION
MXZ-18RV -
E1
●
Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes, refer to the
table below.
●
When diameter of refrigerant pipe is different from that of outdoor unit union, use optional L-joint. For further information on
L-joint, see page BACK COVER.
Indoor unit
Extention pipe diameter
class
Pipe diameter
Liquid
6.35(1/4)
Liquid
6.35(1/4)
07/09
Gas
9.52(3/8)
Gas
9.52(3/8)
Liquid
6.35(1/4)
Liquid
6.35(1/4)
12
Gas
12.7(1/2)
Gas
12.7(1/2)
Outdoor unit union diameter
For
Liquid
6.35(1/4)
Indoor unit A
Gas
9.52(3/8)
Liquid
6.35(1/4)
Indoor unit B
Gas
9.52(3/8)
Unit : mm (inch)
MXZ-32RV -
E1