EMERGENCY OPERATION switch
PROGRAM TIMER
(Example 1) The current time is 8:00 PM.
The unit turns off at 11:00 PM, and on at 6:00 AM.
●
The OFF timer and ON timer can be used in combination.
●
“
” and “ ” display shows the order of the OFF timer and ON timer operation.
(Example 2) The current time is 11:00 AM.
The unit turns on at 5:00 PM, and off at 9:00 PM.
NOTE : TIMER setting will be cancelled by power failure or breaker functioning.
11-9. EMERGENCY-TEST OPERATION
When the remote controller is missing, has failed or the batteries run down, use the EMERGENCY OPERATION switch
on the front of the indoor unit for operation. The unit will start and the Operation Indicator lamp will light.
The first 30 minutes of operation is the test run operation. This operation is for servicing. The indoor fan speed runs at Hi
notch and the system is in continuous operation.(The thermostat is ON.)
After 30 minutes of test run operation the system shifts to EMERGENCY COOL / HEAT
<
MUH-07/09/12RV,MXZ-18/32RV
>
MODE with a set temperature of 24°C.
The fan speed shifts to Me notch.
This operation continues until the EMERGENCY OPERATION switch is pressed once again(MU-07/09/12RV,.MUX-
10/18/24RV)/ once or twice(MUH-07/09/12RV, MXZ-18/32RV) or the unit receives any signal from the remote controller.
In case of latter normal operation will start.
The coil frost prevention works even in this operation, and defrosting
<
MUH-07/09/12RV,MXZ-18/32RV
>
too.
In the test run or emergency operation, the horizontal vane operates in VANE AUTO mode.
NOTE : Do not press the EMERGENCY OPERATION switch during normal operation.
Press once <Cool>
Press again <Heat>
Press once again <Stop>
w
Heat is available only in MUH-07/09/12RV,MXZ-
18/32RV.
2. Cancel
TIMER setting can be cancelled with the ON or OFF TIMER buttons. (“
” or “
”)
To cancel the ON timer, press the “
” button.
To cancel the OFF timer, press the “
” button.
TIMER is cancelled and the display of set time disappears.
OPERATION INDICATOR lamp
(4) Press HR. and MIN. button to set the timer. Time setting is 10-minute units.
HR. and MIN. button will work when “
” or “
” mark is flashing.
These marks disappear in 1 minute.
After setting the ON timer, check that Operation indicator lamp of the indoor unit lights.
NOTE1 : Be sure to place the remote controller at the position where its signal can reach the air conditioner even during
TIMER operation, or the set time may deviate within the range of about 10 minutes.
NOTE2 : Reset the timer in the following cases, or the set time may deviate and other malfunctions may occur.
●
A power failure occurs.
●
The circuit breaker functions.