17
Indoor model
Function
Indoor unit power supply
Air flow(Hi)
Power outlet
Running current
Power input
Power factor
Starting current
Fan motor current
Model
Winding
resistance(at20
:
)
Dimensions W
O
H
O
D
Weight
Air direction
Sound level (Hi)
Fan speed (Hi)
Fan speed regulator
Thermistor RT11(at25
:
)
Thermistor RT12(at25
:
)
W
MSC-07RV -
E1
Single phase
220-240V,50Hz
10
0.17
35
94.0-86.0
—
0.17
RC4V19-BA
WHT-BLK 292
BLK-RED 325
850
O
278
O
191
9
5
3
10
10
Cooling
474
36
950
Heating
504
35
1000
W
MSC-09RV -
E1
Single phase
220-240V,50Hz
10
0.17
35
94.0-86.0
—
0.17
RC4V19-BA
WHT-BLK 292
BLK-RED 325
850
O
278
O
191
9
5
3
10
10
Cooling
474
36
950
Heating
504
35
1000
W
MSC-12RV -
E1
Single phase
220-240V,50Hz
10
0.19
40
96.0-88.0
—
0.19
RC4V19-BA
WHT-BLK 292
BLK-RED 325
850
O
278
O
191
10
5
3
10
10
Cooling
588
39
1020
Heating
642
39
1100
Electrical
data
Fan
motor
Special
remarks
Capacity
W
Refer to the above specification when MSC-07RV -
,MSC-09RV-
and MSC-12RV-
is connected with
MXZ-18RV-
and MXZ-32RV-
as inverter controlled multi system units.
E1
E1
E1
E1
E1
For inverter multi system
NOTE:Test conditions Cooling : Indoor DB27°C / WB19°C
Heating : Indoor
DB20°C
Outdoor DB35°C / WB24°C Outdoor
DB
7°C / WB 6°C