41
MSC-09RV-
MSC-12RV-
E1
E1
MUX-24RV-
E1
Unit : mm
OUTDOOR UNIT
INDOOR UNIT
UNIT A
Indoor
heat
exchanger
Indoor coil
thermistor
RT12
Room
temperature
thermistor
RT11
UNIT B
Indoor
heat
exchanger
Outdoor
heat
exchanger
Indoor coil
thermistor
RT12
Room
temperature
thermistor
RT11
(option)
(With insulation)
Refrigerant pipe
{
12.7 (1/2)
(option)
(With insulation)
Refrigerant pipe
{
12.7 (1/2)
Flared connection
(option)
(With insulation)
Refrigerant pipe
{
6.35 (1/4)
(option)
(With insulation)
Refrigerant pipe
{
6.35 (1/4)
Flared connection
Stop valve
with service port
Solenoid valve
21R1
Solenoid valve
21RA
Solenoid valve
21R2
Capillary tube
{
1.6
x
420
Capillary tube
{
1.6 x 420
Capillary tube
Capillary tube
{
1.8 x 260
{
1.6 x 1,000
Compressor 1
Refrigerant flow
Stop valve
with service port
Stop
valve
Stop
valve
UNIT C
Indoor
heat
exchanger
Indoor coil
thermistor
RT12
Room
temperature
thermistor
RT11
UNIT D
Indoor
heat
exchanger
Indoor coil
thermistor
RT12
Room
temperature
thermistor
RT11
(option)
(With insulation)
Refrigerant pipe
{
9.52 (3/8)
(option)
(With insulation)
Refrigerant pipe
{
9.52 (3/8)
Flared connection
(option)
(With insulation)
Refrigerant pipe
{
6.35 (1/4)
(option)
(With insulation)
Refrigerant pipe
{
6.35 (1/4)
Flared connection
Stop valve
with service port
Solenoid valve
21R3
Solenoid valve
21RB
Solenoid valve
21R4
Capillary tube
{
1.6
x
650
Capillary tube
{
1.6 x 650
Capillary tube
Capillary tube
{
1.6 x 400
{
1.6 x 1,000
Compressor 2
Stop valve
with service port
Stop
valve
Stop
valve
MSC-12RV- E1
MSC-12RV- E1
MSC-09RV- E1
MSC-09RV- E1