128
Measure the resistance between the terminals with a tester.
(Coil wiring temperature10°C ~ 30°C)
Room
temperature
thermistor
10-4.
. Trouble criterion of main parts
Part name
Indoor coil
thermistor
Indoor fan
motor
Motor part
Sensor part
Check method and criterion
Measure the resistance with a tester.
(Part temperature 10°C ~ 30°C)
Measure the voltage Power ON.
Figure
8k
Ω
~ 20k
Ω
Normal
Abnormal
Opened or
short-circuited
280 ~ 304
Ω
WHT-BLK
BLK-RED
BRN-YLW
YLW-GRY
Normal
4.5 ~ 5.5V
Abnormal
Remain 0V or 5V
(When fan revolved one time)
0V
➔
5V
➔
0V
(Approx.)
MSC-07/09/12RV
311 ~ 338
Ω
RED
BLK
YLW
GRY
BRN
WHT
MSC-07RV -
MSC-09RV -
MSC-12RV -
E1
E1
E1
Normal
Abnormal
Opened or
short-circuited
MSC-07/09/12RV
MSC-07/09/12RV
Vane motor
Measure the resistance between the terminals with a tester.
(Part temperature10°C ~ 30°C)
Normal
Abnormal
Opened or short-circuited
282 ~ 306
Ω
RED
YLW
BRN
ORN
GRN
ROTOR
MSC-07/09/12RV