8
NOTE:
1. Rating conditions (ISO T1)
Cooling Indoor : D.B. 27
(80°F) W.B. 19
(66°F) Outdoor : D.B. 35
(95°F) W.B. 24
(75°F)
Heating Indoor : D.B. 20
(68°F)
Outdoor : D.B. 7
(45°F)
W.B. 6
(43°F)
Refrigerant piping length (one way) : 5m (16ft.)
2. Guaranteed operating range
Indoor
Outdoor
Cooling
Upper limit D.B. 35°C, W.B. 22.5°C D.B. 46°C
Lower limit D.B. 19°C, W.B. 15°C
D.B. -5°C
+
1
Heating
Upper limit D.B. 28°C
D.B. 21°C, W.B. 15°C
Lower limit D.B. 17°C
D.B. -11°C, W.B. -12°C
4. Above data are based on the indicated voltage.
+
1. If optional air protect guide is installed : D.B.-15
Indoor unit
3 phase 400V 50Hz
3 phase 400V 50Hz
Outdoor unit
3. Guaranteed voltage
342~457V, 50Hz
Model name
Indoor unit
PEA-RP400GA
PEA-RP500GA
Outdoor unit
PUHZ-P200YHA3
%
2
PUHZ-P250YHA3
%
2
Cooling
Capacity
Btu/h
130,000
150,000
kW
38.0(18.0-44.8)
44.0(22.4-56.0)
Total input
kW
13.97
17.36
EER
2.72
2.53
Energy label class
-
-
Energy label class
-
-
SHF
0.75
0.77
Heating
Capacity
Btu/h
153,000
184,000
kW
44.8(19.0-50.0)
54.0(25.0-63.0)
Total input
kW
14.27
17.42
COP
3.14
3.10
Booster heater
kW
-
-
Power supply
Phase
:
3
Cycle
Hz
50
Voltage
V
400
Breaker size
A
Indoor 15 / Outdoor 32
%
2
Indoor unit
Air flow
CMM
120
160
(High)
CFM
4240
5650
External pressure
Pa
150
Sound level
dB(A)
52
53
(High)
External finish
Galvanized steel
Dimension
W : mm
1947
D : mm
764
H : mm
595
W : inch
79-11/16
D : inch
30-1/8
H : inch
23-7/16
Weight
kg
130
133
lbs
286
293
Unit drain pipe
R1
Outdoor unit
(Per 1 outdoor unit)
Air flow
CMM
130
CFM
4590
Sound level at cooling
dB(A)
59
Sound level at heating
dB(A)
59
External finish
Ivory Munsell 3Y 7.8/1.1
Dimension
W : mm
950
D : mm
330+30
H : mm
1350
W : inch
37-3/8
D : inch
13 + 1-3/16
H : inch
53-1/8
Weight
kg
126
lbs
278
133
294
Refrigerant pipe size
Gas side O.D.
mm
25.4
%
2
inch
1
%
2
Liquid side O.D.
mm
12.7
%
2
inch
1/2
%
2
9.52
%
2
3/8
%
2
Refrigerant pipe length
Height difference
m
Max. 30
Length
m
Max. 70 (per 1 outdoor unit)