39
PEA-RP400, 500GA
GREEN/YELLOW
INDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
TA
B
1
TA
B
1
FA
N
CNDK
31
1
5
73
X4
X5
X6
CN20
CN21
CN41
CN29
1
2
3
4
1
2
1
2
2
1
CN2D
CN90
CN22
CN2L
CND
CN32
CN31
CN51
1
2
3
4
5
FUSE
ZNR
31
31
1
2
DC13.1V
LED1
LED2
LED3
2
1
2
1
2
1
2
1
3
3
6
5
4
9
8
7
3
1
2
CN3C
3
1
CNSK
2
1
CN2S
DC 13.1V
3
1
CNSK
2
1
CN2S
DC
13.1V
CN2D
CN90
CN22
CN2L
FA
N
CNDK
CND
CN32
CN31
CN51
1
2
3
4
5
FUSE
ZNR
31
31
31
1
2
DC13.1V
1
5
73
X4
X5
X6
LED1
LED2
LED3
2
1
2
1
2
1
2
1
3
3
6
5
4
9
8
7
3
1
2
CN3C
CN20
CN21
CN41
CN29
1
2
3
4
1
2
1
2
2
1
FB1
1
S1
1
2
REMOTE CONTROLLER
S2
S3
TB5
TB6
LCD
X1
FB21
S1
S2
S3
X2
TH1-1
TH2-1
TH5-1
TH5-2
TH2-2
TH1-2
TB4-2
TB4-1
FB12
FB22
X4
X5
X6
X4
X5
X6
51F
BLUE
POWER SUPPL
Y
3N~PE 380/400/415V 50Hz
CIRCUIT
BREAKER
(FIELD SUPPL
Y)
PEA-RP400,500GA:15A
BLACK
WHITE
RED
DSR
DSA
N
BLACK
WHITE
RED
TB2
L3
L2
L1
PE
52F
C01
C02
1
2
3
MF1
1
2
3
52F
C01
5
4
X01
X02
49F
SWE
OFF
ON
345
SW1
OFF
ON
5
ON OFF
34
12
2
1
SWE
OFF
ON
345
SW1
OFF
ON
5
ON OFF
SW2
34
12
2
1
SW2
AUXILIAR
Y
RELA
Y
X4-6
MF1
51F
49F
TB2,4-1,4-2,5
TH1-1,1-2
TH2-1,2-2
FA
N MOT
O
R (INDOOR)
OVER CURRENT
RELA
Y
(INDOOR F
A
N MOT
O
R)
INTERNAL
THERMOST
A
T
(INDOOR F
A
N MOT
O
R)
TERMINAL
BLOCK
THERMIST
OR
INDOOR UNIT
FUSE
FUSE (T6.3AL250V)
ZNR
V
ARIST
O
R
TH5-1,5-2
CR
SURGE KILLER
MAGNETIC CONT
ACT
O
R (INDOOR F
A
N MOT
O
R)
52F
ROOM TEMP
.
LIQUID PIPE
TEMP
.
COND./EV
A
. TEMP
.
FERRITE CORE
FB1
1,FB12
FB21,FB22
INDOOR
CONTROLLER
BOARD
X1,2
AUXILIAR
Y
RELA
Y
NAME
SYMBOL
SNB
BOARD 1
ZNR5~7
V
A
RIST
OR
DSA,DSR
A
RRESTER
SW2
SWE
LED1
LED (POWER SUPPL
Y)
LED2
LED (POWER SUPPL
Y<REMOTE CONTROLLER>)
LED3
LED (TRANSMISSION<INDOOR·OUTDOOR>)
SWITCH (MODEL
SELECTION)
SW1
SWITCH (CAP
ACITY
CORD)
CONNECT
OR (EMERGENCY
OPERA
TION)
OUTDOOR UNIT
TERMINAL
BLOCK
NAME
SYMBOL
TB3,TB8
CN2L
CN31
CN90
CN51
CN41
CN32
CONNECT
OR (DRAIN SENSOR)
CONNECT
OR (REMOTE SWITCH)
CONNECT
OR (HA
TERMINAL-A)
CONNECT
OR (CENTRALL
Y
CONTROL)
CONNECT
OR (WIRELESS REMOTE CONTROLLER)
CONNECT
OR (LOSSNA
Y
)
REMOTE CONTROLLER
TERMINAL
BLOCK
NAME
SYMBOL
TB6
4. Indoor and outdoor connecting wires have polarities, make sure to
match wiring and terminal.
5. Emergency operation
If a trouble occurs with either the remote controller or the indoor microcom-
puter and no other trouble exists, emergency operation for cooling or heating
can be performed by changing the setting of connector (SWE) "ON" on the
indoor controller board.
SWE :ON / Indoor fan is running at high speed.
(No.2)
INDOOR
CONTROLLER
BOARD
(No.1)
REMOTE CONTROLLER BOARD
INDOOR POWER BOARD
(No.1)
(No.2)
INDOOR
CONTROLLER
BOARD
(No.2)
T
O
OUTDOOR UNIT
CONNECTING WIRES (POLAR)
T
O
OUTDOOR UNIT
CONNECTING WIRES (POLAR)
SNB BOARD 1
(No.1)
INDOOR POWER BOARD
Note:1.
The dotted lines show field wiring.
2. Color of earth wire is yellow and green twisting.
3. Specification subject to change without notice.
51F
6. mark is connector
. mark is terminal.
Caution,
1.T
o protect fan motor from abnormal current, overcurrent relays are installed.
Therefore, do not change factory set value of overcurrent relays.
CR
ZNR5~7