15. USING A DIRECT DRIVE MOTOR
15 - 9
(c) State transition of the servo amplifier display (3-digit, 7-segment LED) at the magnetic pole detection
When the magnetic pole detection with MR Configurator2 is normally executed, the servo amplifier
display (3-digit, 7-segment LED) shows the state as below.
The decimal point flickers.
Servo-off status
During the
magnetic
pole detection
Magnetic pole
detection
completed
(Servo-on status)
(2) Preparation for the magnetic pole detection
POINT
When you select the test operation mode with the test operation select switch
(SW1-1), the network communication for the servo amplifier and later will be
blocked.
For the magnetic pole detection, use the test operation mode (positioning operation) of MR
Configurator2. Turn off the servo amplifier power, and set the test operation select switch (SW1-1) as
shown below. Turning on the power enables the test operation mode.
1
ON
2
Set SW1-1 to "ON (up)".
1
ON
2
Summary of Contents for MR-J4 TM Series
Page 9: ...A 8 MEMO ...
Page 17: ...8 MEMO ...
Page 225: ...5 PARAMETERS 5 86 MEMO ...
Page 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Page 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Page 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Page 578: ...APPENDIX App 41 ...