11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 68
(b) 400 V class
Table 11.2 Wire size selection example (HIV wire)
Servo amplifier
Wires
[mm
2
] (Note 1)
1) L1/L2/L3/
2) L11/L21
3) P+/C
4) U/V/W/
(Note 3)
MR-J4-60TM4/
MR-J4-100TM4
2 (AWG 14)
1.25 to 2
(AWG 16 to 14)
(Note 4)
2 (AWG14)
AWG 16 to 14
MR-J4-200TM4
MR-J4-350TM4
MR-J4-500TM4
(Note 2)
2 (AWG 14): b
1.25 (AWG 16): a
2 (AWG 14): c
(Note 4)
2 (AWG14): b
3.5 (AWG 12): a
MR-J4-700TM4
(Note 2)
3.5 (AWG 12): a
5.5 (AWG 10): a
MR-J4-11KTM4
(Note 2)
5.5 (AWG 10): d
1.25 (AWG 16): b
2 (AWG 14): b
(Note 4)
2 (AWG14): f
8 (AWG 8): g
MR-J4-15KTM4
(Note 2)
8 (AWG 8): g
3.5 (AWG 12): d
MR-J4-22KTM4
(Note 2)
14 (AWG 6): i
3.5 (AWG 12): e
5.5 (AWG 10): e
(Note 5)
8 (AWG 8):h
(Note 6)
14 (AWG 6): i
Note 1. Alphabets in the table indicate crimping tools. For crimp terminals and applicable tools, refer to (2)
in this section.
2. To connect these models to a terminal block, be sure to use the screws that come with the
terminal block.
3. The wire size shows applicable size of the servo amplifier connector and terminal block. For wires
connecting to the servo motor, refer to each servo amplifier instruction manual.
4. Be sure to use the size of 2 mm
2
when corresponding to IEC/EN/UL/CSA standard.
5. This is for connecting to the linear servo motor with natural cooling method.
6. This is for connecting to the linear servo motor with liquid cooling method.
Use wires (5)) of the following sizes with the power regeneration converter (FR-RC-H).
Model Wire
[mm
2
]
FR-RC-H15K
14 (AWG6)
FR-RC-H30K
FR-RC-H55K
(c) 100 V class
Table 11.3 Wire size selection example (HIV wire)
Servo amplifier
Wires
[mm
2
]
1) L1/L2/
2) L11/L21
3) P+/C
4) U/V/W/
(Note 1)
MR-J4-10TM1
2 (AWG 14)
1.25 to 2
(AWG 16 to 14)
(Note 2)
2 (AWG 14)
AWG 18 to 14
(Note 2)
MR-J4-20TM1
MR-J4-40TM1
Note 1. The wire size shows applicable size of the servo amplifier connector and terminal block. For wires
connecting to the servo motor, refer to each servo amplifier instruction manual.
2. Be sure to use the size of 2 mm
2
when corresponding to IEC/EN/UL/CSA standard.
Summary of Contents for MR-J4 TM Series
Page 9: ...A 8 MEMO ...
Page 17: ...8 MEMO ...
Page 225: ...5 PARAMETERS 5 86 MEMO ...
Page 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Page 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Page 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Page 578: ...APPENDIX App 41 ...