11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 69
(2) Selection example of crimp terminals
(a) 200 V class
Symbol
Servo amplifier-side crimp terminals
(Note 2) Crimp
terminal
Applicable tool
Manufacturer
Body Head Dice
a FVD5.5-4
YNT-1210S
JST
b (Note 1) 8-4NS
YHT-8S
c FVD2-4
YNT-1614
d FVD2-M3
e FVD1.25-M3 YNT-2216
f FVD14-6
YF-1
YNE-38
DH-122
DH-112
g FVD5.5-6
YNT-1210S
h FVD22-6
YF-1
YNE-38
DH-123
DH-113
i FVD38-8
YF-1
YNE-38
DH-124
DH-114
j FVD5.5-8
YNT-1210S
k
FVD8-6
YF-1/E-4
YNE-38
DH-121
DH-111
Note 1. Coat the crimping part with an insulation tube.
2. Some crimp terminals may not be mounted depending on the size. Make sure to use the
recommended ones or equivalent ones.
(b) 400 V class
Symbol
Servo amplifier-side crimp terminals
Manufacturer
Crimp terminal
(Note)
Applicable
tool
Body Head Dice
a FVD5.5-4
YNT-1210S
JST
b FVD2-4
YNT-1614
c FVD2-M3
d FVD5.5-6
YNT-1210S
e FVD5.5-8
YNT-1210S
f FVD2-6
YNT-1614
g FVD8-6
YF-1 YNE-38
DH-121/DH-111
h FVD8-8
i FVD14-8
DH-122/DH-112
Note. Some crimp terminals may not be mounted depending on the size. Make sure to use the
recommended ones or equivalent ones.
11.10 Molded-case circuit breakers, fuses, magnetic contactors
CAUTION
To prevent the servo amplifier from smoke and a fire, select a molded-case circuit
breaker which shuts off with high speed.
Always use one molded-case circuit breaker and one magnetic contactor with one
servo amplifier.
POINT
For the selection when the servo amplifier is used with the DC power supply
input, refer to app. 1.4.