4 - 15
4. OPERATION
Dwell
time (an)
Point table No. n
Dwell
time
(an 1)
Point table No. n+1
Point table No. n 2
Servo motor speed
Point table selection
No.n
In position (INP)
Rough match (CPO)
Forward rotation start (ST1)
or reverse rotation start (ST2)
Point Table No.
Dwell Time [ms] (Note 1)
Auxiliary Function
n
an
1
n 1
an 1
1
n 2
Invalid
0 (Note 2)
Note: 1. Always set "1" or more.
2. Always set "0" to the auxiliary function of the last point table among the consecutive point tables.