4. SSCNET COMMUNICATION DRIVERS
4
−
6
4.1.3
When using the A10BD-PCF interface board
This section provides the SSCNET communication driver setup procedure for use
of the interface board.
1) The SSCNET Communication Driver Setup window
appears.
Choose "A10BD-PCF Board Type" and click [Detail].
*1:You need not make the setting when you use the
A10BD-PCF interface board.
*2:You need not make the setting when you use
RS232C communication or do not use SSCNET
communication.
Click [Cancel] to exit from SSCNET
Communication Driver Setup.
2) The left dialog box appears.
<For Windows NT>
Click [No].
Choose "Shut Down" in the Start menu to power off
the personal computer.
After making sure that the power is off, confirm the
switch setting of the interface board and load the
interface board into the personal computer.
<For Windows 98>
Click [No].
Choose "Shut Down" in the Start menu to power off
the personal computer.
After making sure that the power is off, confirm the
switch setting of the interface board and load the
interface board into the personal computer.
3) After Windows NT/98 has restarted, choosing and
clicking [Programs]-[SWnRNC-GSVE]-[SW3RNC-
GSVE]-[SW3RN-SNETP]-[Start SSCNET Task] in
the Start menu makes SSCNET communication
ready to start.