128
6 WIRING
6.7 Examples of Wiring for Various Uses
When BIN instructions are used
Examples of wiring for capturing values from a 2-digit digital switch to the data register D102 are given below.
For the instructions, refer to
MELSEC iQ-F FX5 Programming Manual (Instructions, Standard Functions/Function Blocks).
■
Example of program
■
Example of wiring
• Sink wiring
The example is the wiring for the input/output of the FX5UC-32MT/D.
• Source wiring
The example is the wiring for the input/output of the FX5UC-32MT/DSS.
*1 The grounding resistance should be 100
or less.
BIN
SM400
K2X10 D102
COM X10 X11
X12 X13
X15
X14
X16 X17
1
2
4
8
1
2
4
8
10
1
10
0
Fuse
24 V DC
Class D
grounding
*1
FX5UC-32MT/D
COM0 X10 X11 X12 X13
X15
X14
X16 X17
1
2
4
8
1
2
4
8
10
1
10
0
Fuse
24 V
DC
Class D
grounding
FX5UC-32MT/DSS
Source input