5. CONNECTION OF UNIT
5.7 Connection of Machine Input/Output Signal
I
-17
5.7 Connection of Machine Input/Output Signal
Input Output
Number of occupied serial
link stations
Machine input/output signal
types and number of points
44 points
32 points
2
Machine signal
Machine signal
R300 cable/
R301 cable
R300 cable/
R301 cable
DI-L
DO-L
DI-R
[Outline of connection]
X00 to X07 and Y00 to Y37 below are indicated as octal values.
B3
Input circuit
sink type
A3
DI_COM
3.3k
Ω
:4 points (X04 to X07)
4.3k
Ω
:40 points (X10 to X57)
DI_0V
DI_24V
RIO1
RIO2
1 2
Stabilized
power supply
DCIN
3
0V
24VDC (+)
FG
B4
A4
Control
circuit
RA
PL
B3
DO_COM
A3
DO_24V
DO_0V
B4
A4
Output circuit
sink type
DI-L/R
DO-L
Machine
control panel
B3
Input circuit
A3
Control
circuit
Output circuit
RA
PL
source type
source type
RIO1
RIO2
1 2
Stabilized
power supply
DCIN
3
0V
24VDC (+)
FG
B3
DO_COM
A3
DO_24V
DO_0V
DI_0V
DI_24V
DI_COM
B4
A4
B4
A4
3.3k
Ω
:4 points (X04 to X07)
4.3k
Ω
:40 points (X10 to X57)
DI-L/R
DO-L
Machine
control panel
The input circuit can be switched to a sink type or source type with the connections.
The output circuit is fixed to the source type.
Incorrect connections could damage the device, so always connect the cable to the
designated connector.
Do not connect or disconnect the connection cables between each unit while the power is
ON.
CAUTION
Downloaded from