- 54 -
Installation 2. Mounting
1
Dimensions of mounting holes
The drilling dimensions of the panel are as shown in the right figure.
The product can be installed to a panel having a thickness of
1.6 to 4.0 mm.
2
Mounting position
The contrast of the LCD changes depending on the angle at which
it is viewed.
Mount the product in the easy viewable position.
3
Mounting and fixing
Mount the product to the panel of the main unit according to the following procedure.
Note
Protecting sheet
The LCD part is covered with a protecting sheet to avoid scratches to the LCD during
mounting of the panel. Before starting operation, remove the sheet. When removing the
sheet, the LCD may illuminate due to static electricity, but this is not a product failure. After
a while, the LCD goes off as it naturally discharges electricity.
Mounting position
To mount the product to the edge of the panel, check the space for wiring work before
determining the mounting position.
①
Attach the mounting brackets to two areas
each in upper and lower parts of the main unit.
②
Tighten the screws of the mounting
brackets to fix them to the panel.
Screw type for mounting to the main unit: M3
Note
To avoid damage to the panel
and screws, do not
overtighten the screws.
The recommended torque for
this product is 0.3 N•m to 0.5
N•m (about half the normal
torque).
Tighten the upper and lower
screws evenly.