- 14 -
3. Setting
3.1 Setting flow
<Setting Procedure>
①
Press
and
simultaneously for 2
⑤
A
fter completion of setting
, select ‘End’ in the setting
seconds to get in the setting mode. menu and press
.
②
Select a setting menu number by or .
⑥
When the End display appears, press
once again.
③
Use the
button to select a setting menu number.
④
Set each setting item. (Refer to page 15 and later
pages.)
Arrow in Figure
Action
Button operation
Shift from the operation mode to the setting mode.
+
Press them simultaneously
Shift from the operation mode to the set value confirmation mode.
Press it for 2 seconds.
Select the menu number to set or “End”.
or
Press it several times.
Get into each setting screen. Shift to the next setting item.
Press it.
Go back to the previous setting item.
Press it.
Omitted in figure
Select a set value.
or
Press it several times.
Shift to the End screen.
Press it.
Memorize the setting contents, and go back to the operation mode.
Press it.
Select "CANCEL."
or
Press it.
Cancel the settings.
Press it.
Skip remaining setting items during setting.
Press it for 1 second.
Set values return to the factory default value.
+
Press it for 2 seconds.
Shift from the operation mode to the password protection mode.
+
Press it for 2 seconds.
Alarm value
Alarm delay
time
Alarm cancel
method
Back light flickers
during alarms
Alarm item
Motor starting
current delay time
Model +
option code
Version
display
Backlight
brightness
Backlight
auto off
Display
update tim
e
non
non
Operation time
threshold
Set IEC
mode
Phase display
setting
Operation time
display
Target for
counting operation
time setting
Setting Value
Confirmation Menu
9
Setting Menu
4
Setting Menu
5
Setting Menu
6
Setting Menu
7
Setting Menu
8
Setting Mode or Setting Value Confirmation Mode
DISPLAY
RESET
+
-
SET
PHASE
RESET
SET
SET
SET
SET
+
-
SET
SET
※
1
.
If the password protection setting is enabled,
it is necessary to enter the password in shift from
the operation mode to the setting mode.
※
2
.
For Setting Value Confirmation, it returns to
Operation Mode.
※
3
.
This is not display in Setting Mode.
Test Mode
※
3
PHASE
RESET
Automatic migration
Automatic migration
+
-
※
3
SET
+
-
SET
SET
SET
RESET