5 Introduction of Functions
5.10 Application Profile CiA
®
417 V2.1 for Lift Control Systems
104
FX
3U
-CAN User's Manual
Status transition
Note
• At the following Transition numbers occur a automatic status transition: 0, 1, 13, 14
• Automatic transition to enable operation state after executing SWITCHED ON state functionality.
Command
Bits of the control word
Transition No.
Bit 7
Bit 3
Bit 2
Bit 1
Bit 0
Shutdown
0
X
1
1
0
2, 6, 8
Switch on
0
0
1
1
1
3
Switch on + enable operation
0
1
1
1
1
3 + 4 (Note)
Disable voltage
0
X
X
0
X
7, 9, 10, 12
Quick stop
0
X
0
1
X
7, 10, 11
Disable operation
0
0
1
1
1
5
Enable operation
0
1
1
1
1
4, 16
Fault reset
0
→
1
X
X
X
X
15
Number: Transition No.
Power
disabled
0
1
2
3
8
9
10
15
12
13
14
11
16
4
5
6
7
Fault
Power
enabled
Start
Fault reaction
active
Fault
Not ready to
switch on
Switch on
disabled
Ready to
switch on
Switched on
Operation
enabled
Quick stop
active