5 Introduction of Functions
5.10 Application Profile CiA
®
417 V2.1 for Lift Control Systems
102
FX
3U
-CAN User's Manual
2. Battery power field
3. Door lock field
4. Finger protector field
5. Motion detector field
6. Force limit field
7. Status field
Note
If the door is in an open or closed end position, this shall have higher priority than stopped status.
Bit 2 to 3 Value (hex)
Description
0
No battery power used
1
Battery power used
2
Error indicator
3
Not available or not installed
Bit 4 to 5 Value (hex)
Description
0
Door not locked
1
Door locked
2
Error indicator
3
Not available or not installed
Bit 6 to 7 Value (hex)
Description
0
No finger detected
1
Finger detected
2
Error indicator
3
Not available or not installed
Bit 8 to 9 Value (hex)
Description
0
Motion not detected
1
Motion detected
2
Error indicator
3
Not available or not installed
Bit 10 to 11 Value (hex)
Description
0
Force limit not reached
1
Force limit reached
2
Error indicator
3
Not available or not installed
Bit 12 to 15 Value (hex)
Description
0
Door closed with torque
1
Door closed without torque
2
Door is closing
3
Door opened with torque
4
Door opened without torque
5
Door is opening
6
Door is re-opening
7
Door stopped with torque
(not in an end position)
8
Door stopped without torque
(not in an end position)
9 to C
Reserved
D
Tech-in drive
E
Error indicator
F
Not available or not installed
Summary of Contents for FX3U-CAN