5 Introduction of Functions
5.10 Application Profile CiA
®
417 V2.1 for Lift Control Systems
95
FX
3U
-CAN User's Manual
1
Introduc
tion
2
Specifi
cations
3
Inst
allati
on
4
Wi
rin
g
5
Introduc
tion of
Functions
6
All
ocation of
B
uff
er
Memor
ies
7
Interface and
D
evice P
rofile
(40
5 mode)
8
Lift Appl
icati
on
P
ro
file
(417 M
ode)
9
CAN
Layer 2
Mode
10
Comm
and
Interface
5.10.2 Virtual input mapping
This Object contains the last received input data from one of the digital input panel group objects.
1. Basic function field
2. Sub-function field
The Sub-function field is interpreted differently depending on the basic function field value.
Bit 0 to 7
Value (hex)
Description
Bit 0 to 7
Value (hex)
Description
00
Reserved
0D
High priority call to destination floor
01
Generic input
0E
Special function
02
Standard hall call request
0F
Access code upload request
03
Low priority hall call request
10
Speech connection request
04
High priority hall call request
11
Area monitoring connection request
05
Standard car call request
12
Fire detector
06
Low priority car call request
13 to 15
Reserved
07
High priority car call request
16
Status of safety-related circuitries
(This is not safety-related information.)
08
Standard destination call
09
Low priority destination call
17 to 1F
Reserved
0A
High priority destination call
20
Guest call
0B
Standard call to destination floor
21 to 7F
Reserved
0C
Low priority call to destination floor
80 to FF
Manufacturer-specific
Basic function
field Bit 0 to 7
value (hex)
Sub-function
field Bit 8 to
15 value (hex)
Description
Basic function
field Bit 0 to 7
value (hex)
Sub-function
field Bit 8 to
15 value (hex)
Description
01
00
Reserved
0E
12
Special service
01
Generic input 1
13
Service run
…
…
14
Dogging service enable
FE
Generic input 254
15
Dogging service up
FF
Reserved
16
Dogging service down
02 to 04
00
Reserved
17
Fire alarm (external fire alarm system)
01
Hall call up
18
Provide priority
02
Hall call down
19
Lift attendant start button
03
Hall call
1A
Lift attendant drive through button
04
Hall call extra up
1B
Security run
05
Hall call extra down
1C
Second call panel
06
Hall call extra
1D
Door enable
07 to FF
Reserved
1E
Call cancel button fire operation
05 to 0D
00
Reserved
1F
Fire alarm reset
01 to FE
Floor number 1 to 254
20
Body detector (e.g. person in car)
FF
Reserved
21
Earthquake detector
0E
00
Reserved
22 to FF
Reserved
01
Request fan 1
0F to 11
00 to FF
Reserved
02
Request fan 2
12
00
Reserved
03
Request load time 1
01 to FE
Fire detector 1 to 254
04
Request load time 2
FF
Reserved
05
Key lock 1
13 to 15
00 to FF
Reserved
06
Key lock 2
16
00
Reserved
07
Key lock 3
01 to 03
Safety-related circuitry 1 to 3
08
Key lock 4
04
Hall/swing door
09
Request door open
05
Car door
0A
Request door close
06
Door lock
0B
Fire recall (key switch hall panel)
07 to FF
Reserved
0C
Fire service (key switch car panel)
17 to 1F
00 to FF
Reserved
0D
Hall call disable
20
00
Reserved
0E
Attendant service
01 to FE
Guest call 1 to 254
0F
VIP service
FF
Reserved
10
Out of order
21 to 7F
00 to FF
Reserved
11
Bed passenger service
80 to FF
00 to FF
Manufacturer-specific
Function data
Door
Floor
Lift
Sub-function
Basic function
47 ... 40
39 ... 32
31 ... 24
23 ... 16
15 ... 8
7 ... 0
Summary of Contents for FX3U-CAN
Page 1: ...FX3U CAN USER S MANUAL ...
Page 2: ......
Page 6: ...Safety Precautions Read these precautions before use 4 MEMO ...
Page 227: ......