Parameter list (by function group)
8
2.2
Parameter list (by function group)
D: Operation command and
frequency command
Parameters that specify the inverter's command source, and
parameters that set the motor driving frequency and torque.
The setting is available for the FR-A800-E only.
H: Protective function parameter
Parameters to protect the motor and the inverter.
The setting is available for the FR-A800-E only.
M: Monitor display and monitor
output signal
Parameters regarding the inverter's operating status. These
parameters are used to set the monitors and output signals.
N: Operation via communication
and its settings
Parameters for communication operation. These parameters
set the communication specifications and operation.
Pr.
group
Pr.
Name
Refer
to
page
D012
550
NET mode operation command
source selection
D013
551
PU mode operation command
source selection
D400
Torque command source selection
Pr.
group
Pr.
Name
Refer
to
page
H700
Torque limit input method selection
Pr.
group
Pr.
Name
Refer
to
page
M400
190
RUN terminal function selection
M401
191
SU terminal function selection
M402
192
IPF terminal function selection
M403
193
OL terminal function selection
M404
194
FU terminal function selection
M405
195
ABC1 terminal function selection
M406
196
ABC2 terminal function selection
M410
313
DO0 output selection
M411
314
DO1 output selection
M412
315
DO2 output selection
Pr.
group
Pr.
Name
Refer
to
page
N001
342
Communication EEPROM write
selection
N010
349
Communication reset selection
N013
502
Stop mode selection at
communication error
N014
779
Operation frequency during
communication error
N100
541
Frequency command sign selection
N103
544
CC-Link extended setting
N600
1434
Ethernet IP address 1
N601
1435
Ethernet IP address 2
N602
1436
Ethernet IP address 3
N603
1437
Ethernet IP address 4
N610
1438
Subnet mask 1
N611
1439
Subnet mask 2
N612
1440
Subnet mask 3
N613
1441
Subnet mask 4
N630
1427
Ethernet function selection 1
N631
1428
Ethernet function selection 2
N632
1429
Ethernet function selection 3
N641
1426
Link speed and duplex mode
selection
N642
1455
Keepalive time
N643
1431
Ethernet signal loss detection
function selection
N644
1432
Ethernet communication check time
interval
N650
1424
Ethernet communication network
number
N651
1425
Ethernet communication station
number
N660
1442
Ethernet IP filter address 1
N661
1443
Ethernet IP filter address 2
N662
1444
Ethernet IP filter address 3
N663
1445
Ethernet IP filter address 4
N664
1446
Ethernet IP filter address 2 range
specification
N665
1447
Ethernet IP filter address 3 range
specification
N666
1448
Ethernet IP filter address 4 range
specification
N670
1449
Ethernet command source selection
IP address 1
N671
1450
Ethernet command source selection
IP address 2
N672
1451
Ethernet command source selection
IP address 3
N673
1452
Ethernet command source selection
IP address 4
N674
1453
Ethernet command source selection
IP address 3 range specification
N675
1454
Ethernet command source selection
IP address 4 range specification
N681
1124
Station number in inverter-to-
inverter link
N682
1125
Number of inverters in inverter-to-
inverter link system
Pr.
group
Pr.
Name
Refer
to
page