69
APPENDIX
Safety communication model
A.2.4 Capacitor discharge time
Inverter model
Cat. No
Manufacturer
Rating
Inverter model
Cat. No
Manufacturer
Rating
FR-E820-0008(0.1K),
0015(0.2K)
170M1408,
170M1308 or
170M1358
Bussmann
700 V, 10 A
FR-E840-0060(2.2K)
170M1312
Bussmann
700 V, 32 A
FR-E820-0030(0.4K)
170M1409,
170M1309 or
170M1359
Bussmann
700 V, 16 A
FR-E840-0095(3.7K)
170M1413
Bussmann
700 V, 40 A
FR-E820-0050(0.75K)
170M1411,
170M1311 or
170M1361
Bussmann
700 V, 20 A
FR-E840-0120(5.5K)
170M1414
Bussmann
700 V, 50 A
FR-E820-0080(1.5K)
170M1413,
170M1313 or
170M1363
Bussmann
700 V, 32 A
FR-E840-0170(7.5K)
170M1416
Bussmann
700 V, 80 A
FR-E820-0110(2.2K)
170M1414,
170M1314 or
170M1364
Bussmann
700 V, 50 A
FR-E840-0230(11K)
170M1419,
170M1319 or
170M1469
Bussmann
700 V, 160 A
FR-E820-0175(3.7K)
170M1416,
170M1316 or
170M1366
Bussmann
700 V, 80 A
FR-E840-0300(15K)
170M1419,
170M1319 or
170M1469
Bussmann
700 V, 160 A
FR-E820-0240(5.5K)
170M1418,
170M1318 or
170M1368
Bussmann
700 V, 100 A
FR-E840-0380(18.5K)
170M1420,
170M1320 or
170M1370
Bussmann
700 V, 200 A
FR-E820-0330(7.5K)
170M1419,
170M1319 or
170M1369
Bussmann
700 V, 160 A
FR-E840-0440(22K)
170M1421,
170M1321 or
170M1471
Bussmann
700 V, 250 A
FR-E820-0470(11)
170M1420,
170M1320 or
170M1370
Bussmann
700 V, 200 A
FR-E820S-0008(0.1K)
170M1408
Bussmann
700 V, 10 A
FR-E820-0600(15K)
170M1421,
170M1321 or
170M1471
Bussmann
700 V, 250 A
FR-E820S-0015(0.2K)
170M1409
Bussmann
700 V, 16 A
FR-E820-0760(18.5K)
170M1422,
170M1322 or
170M1472
Bussmann
700 V, 315 A
FR-E820S-0030(0.4K)
170M1411
Bussmann
700 V, 25 A
FR-E820-0900(22K)
170M1422,
170M1322 or
170M1472
Bussmann
700 V, 315 A
FR-E820S-0050(0.75K) 170M1413
Bussmann
700 V, 40 A
FR-E840-0016(0.4K)
170M1408
Bussmann
700 V, 10 A
FR-E820S-0080(1.5K)
170M1415
Bussmann
700 V, 63 A
FR-E840-0026(0.75K),
0040(1.5K)
170M1409
Bussmann
700 V, 16 A
FR-E820S-0110(2.2K)
170M1417
Bussmann
700 V, 100 A
CAUTION
l
Risk of Electric Shock
Before wiring or inspection, check that the LED display of the operation panel is OFF. Any person who is involved in wiring or
inspection shall wait for 10 minutes or longer after power OFF, and check that there are no residual voltage using a digital multimeter
or the like. The capacitor is charged with high voltage for some time after power OFF, and it is dangerous.
Summary of Contents for 800 Series
Page 10: ...4 INSTALLATION AND INSTRUCTIONS ...
Page 46: ...40 BASIC OPERATION ...
Page 64: ...58 INVERTER FAULT AND ALARM INDICATIONS ...
Page 70: ...64 SPECIFICATIONS ...