45
PARAMETER LIST
193
NET Y1 output
selection
0, 1, 3, 4, 7, 8,
11 to 16, 20, 24
to 26, 30 to 36,
38 to 41, 44 to
48, 56, 57, 60 to
64, 70, 80, 81,
84, 90 to 93, 95,
98 to 101, 103,
104, 107, 108,
111 to 116, 120,
124 to 126, 130
to 136, 138 to
141, 144 to 148,
156, 157, 160 to
164, 170, 180,
181, 184, 190 to
193, 195, 198,
199, 206, 211 to
213, 242 [E800-
(SC)E], 306,
311 to 313, 342
[E800-(SC)E],
9999
9999
194
NET Y2 output
selection
9999
195
NET Y3 output
selection
9999
196
NET Y4 output
selection
9999
198
Display corrosion
level
(1 to 3)
1
Parameter 200 to 299
Para-
meter
Name
Setting Range
Initial
Value
*1
232 to
239
Multi-speed setting
(speed 8 to speed 15)
0 to 590 Hz,
9999
9999
240
Soft-PWM operation
selection
0, 1
1
241
Analog input display
unit switchover
0, 1
0
244
Cooling fan
operation selection
0, 1
1
245
Rated slip
0% to 50%,
9999
9999
246
Slip compensation
time constant
0.01 to 10 s
0.5 s
247
Constant output
range slip
compensation
selection
0, 9999
9999
249
Earth (ground) fault
detection at start
0, 1
Gr.1: 0
Gr.2: 1
250
Stop selection
0 to 100 s, 1000
to 1100 s, 8888,
9999
9999
251
Output phase loss
protection selection
0, 1
1
255
Life alarm status
display
(0 to 879)
0
256
Inrush current limit
circuit life display
(0% to 100%)
100%
257
Control circuit
capacitor life display
(0% to 100%)
100%
258
Main circuit
capacitor life display
(0% to 100%)
100%
259
Main circuit
capacitor life
measuring
0, 1
0
260
PWM frequency
automatic
switchover
0, 10
10
261
Power failure stop
selection
0 to 2
0
Para-
meter
Name
Setting Range
Initial
Value
*1
267
Terminal 4 input
selection
0 to 2
0
268
Monitor decimal
digits selection
0, 1, 9999
9999
269
Parameter for manufacturer setting. Do not set.
270
Stop-on-contact
control selection
0, 1, 11
0
275
Stop-on contact
excitation current
low-speed scaling
factor
0% to 300%,
9999
9999
276
PWM carrier
frequency at stop-on
contact
0 to 9, 9999
9999
277
Stall prevention
operation current
switchover
0, 1
0
278
Brake opening
frequency
0 to 30 Hz
3 Hz
279
Brake opening
current
0% to 400%
130%
280
Brake opening
current detection
time
0 to 2 s
0.3 s
281
Brake operation time
at start
0 to 5 s
0.3 s
282
Brake operation
frequency
0 to 30 Hz
6 Hz
283
Brake operation time
at stop
0 to 5 s
0.3 s
284
Deceleration
detection function
selection
0, 1
0
285
Overspeed detection
frequency
0 to 30 Hz, 9999
9999
Speed deviation
excess detection
frequency
286
Droop gain
0% to 100%
0%
287
Droop filter time
constant
0 to 1 s
0.3 s
289
Inverter output
terminal filter
5 to 50 ms,
9999
9999
290
Monitor negative
output selection
0, 1, 4, 5, 8, 9,
12, 13
0
292
Automatic
acceleration/
deceleration
0, 1, 7, 8, 11
0
293
Acceleration/
deceleration
separate selection
0 to 2
0
295
Frequency change
increment amount
setting [E800]
0, 0.01, 0.1, 1,
10,
0
296
Password lock level
0 to 6, 99, 100
to 106, 199,
9999
9999
297
Password lock/
unlock
(0 to 5), 1000 to
9998, 9999
9999
298
Frequency search
gain
0 to 32767,
9999
9999
299
Rotation direction
detection selection
at restarting
0, 1, 9999
0
Para-
meter
Name
Setting Range
Initial
Value
*1