V 20.01
23
English
5.
Additional Settings
5.4
Hand disinfection timer
The hand disinfectant timer is designed to assist users to properly disinfectant hands
according to hand hygiene guidelines. Once the user has received a dose of disin-
fectant, the disinfectant (orange) sector starts flashing for a preset amount of time.
Different lengths of time can be selected using the remote control. The user should
thoroughly rub hands with disinfectant for the entire duration that the disinfectant
(orange) sector is flashing. If the user re-selects the disinfectant (orange) sector while it
is blinking, this will interrupt and end the timer.
Press the buttons indicated in the following order: «SPOOL» button, «LIQUID 2»
button, «LANG» button. With the «+» and «-» buttons, the duration the disinfectant
(orange) sector remains blinking can be changed. To save settings, press the «SAVE»
button. All colored LED lights illuminate to indicate the new setting has been saved. If
the «SAVE» button is not pressed within 10 seconds of the last selection, the previously
saved setting will be stored.
5.5
Hand washing timer
The hand washing timer is designed to assist users to properly wash hands with soap
according to hand hygiene guidelines. Once the user has received a dose of soap,
the soap (green) sector starts flashing for a preset amount of time. Different lengths of
times can be selected using the remote control. The user should thoroughly scrub and
lather hands with soap for the entire duration that the soap (green) sector is flashing.
Users can activate the water sector to rinse hands once the soap (green) sector is no
longer flashing. If the user re-selects the soap (green) sector while it is blinking, this will
interrupt and end the timer.
Press the buttons indicated in the following order: «LIQUID 1» button, «LIQUID 1»
button, «LANG» button. With the «+» and «-» buttons, the duration the soap (green)
sector remains blinking can be changed. To save settings, press the «SAVE» button. All
colored LED lights illuminate to indicate the new setting has been saved. If the «SAVE»
button is not pressed within 10 seconds of the last selection, the previously saved
setting will be stored.
LIQUID 2
LANG
SPOOL
LIQUID 1
LANG
LIQUID 1
Position
1
2
3
4
5
6
7
8
9
Bar position
Min
Max
Hand disinfection timer
in seconds
0
20
30
40
50
60
90
105
120
CLASSIC (v.1.61+)
Ä
KITCHEN (v.1.61+)
Ä
Hand washing timer
in seconds
0
20
25
30
35
40
45
50
55
CLASSIC (v.1.61+)
Ä
LIGHT (v.1.23+)
Ä
KITCHEN (v.1.61+)
Ä
These functions are available with faucet software version starting from version number indicated next to each model.