V 20.01
21
English
5.
Additional Settings
5.1
Manual Flush
The manual flush is intended to allow the user to immediately purge the water from
the water line for a set amount of time by using the remote control. Press the buttons
indicated in the following order: «SPOOL» button, «LANG» button, «SAVE» button.
The faucet will begin to purge water for the length of time specified in “
duration of
automatic spool cycle”
.
NOTE
Before using the manual flush function, ensure the duration of the spool cycle setting
is not set to 0 minutes. Please refer to
“3.10 Change duration of automatic spool
cycle”
.
While the system is in manual flush, activating any of the sectors on the faucet will
prematurely interrupt and end the flushing process.
SPOOL
LANG
SAVE
5.2
Automatic Stagnation Flush After Power On
NOTE
Before using this function, ensure the duration of the spool cycle setting is not set to
0 minutes. Please refer to
“3.10 Change duration of automatic spool cycle”
of the
remote control manual.
The Automatic Stagnation Flush at Power On is particularly useful in situations where
miscea sensor faucet systems are not continuously connected to power. Enabling this
function will safeguard water quality by purging stagnant water. When this function is
enabled, after power on, the miscea system automatically begins to purge the water
line for a specified length of time. This length of time is referred to as “the duration of
the automatic spool cycle” and can also be adjusted using the remote control.
Press the buttons indicated in the following order: «MEMO» button, «MEMO» button,
«LANG» button. With the «+» and «-» buttons, select between enable and disable. To
save settings, press the «SAVE» button. All colored LED lights illuminate to indicate the
new setting has been saved. If the «SAVE» button is not pressed within 10 seconds of
the last selection, the previously saved setting will be stored.
MEMO
LANG
MEMO
Position
1
2
3
4
5
6
7
8
9
Bar position
Manual Flush
OFF
ON
Stagnation Flush after Power On
OFF
ON
CLASSIC (v.1.61+)
Ä
LIGHT (v.1.23+)
Ä
KITCHEN (v.1.61+)
Ä
These functions are available with faucet software version starting from version number indicated next to each model.