22
5.
Additional Settings
5.3
IR Sensor Sensitivity
It is possible to increase or decrease the detection range of the sensors on miscea
sensor faucets using the miscea remote control. Detection range is measured starting
from the IR sensor to the point an object is first detected.
Press the buttons indicated in the following order: «SPOOL» button, «DEFAULT»
button, «LANG» button. With the «+» and «-» buttons, the sensor sensitivity can be
changed. To save settings, press the «SAVE» button. All colored LED lights illuminate
to indicate the new setting has been saved. If the «SAVE» button is not pressed within
10 seconds of the last selection, the previously saved setting will be stored.
NOTE
Measurements in table are approximate and should only be used as a guide. Other
factors such as lighting, the wash basin material, shape and form can affect the sensi
-
tivity of the IR sensors and may not reflect the measurements in the table exactly.
Please position the miscea remote control as shown in the images below for the
relevant miscea models.
SPOOL
DEFAULT
LANG
30 º
ma
x. 3
0cm
CLASSIC / KITCHEN
miscea LIGHT
Position
1
2
3
4
5
6
7
8
9
Bar position
Min
Max
IR Sensor Sensitivity
in cm
2
2.5
4
4.5
8
9
10
11
12
CLASSIC (v.0.38+)
Ä
LIGHT (v.0.14+)
Ä
KITCHEN (v.0.38+)
Ä
This function is available with faucet software version starting from version number indicated next to each model.