GUIDE TO INSTALLATION AND OPERATION
84
| XVP-3901
•
In this panel, select which programs will be active using the PGM 1 to PGM 4 checkboxes.
•
The tabs for the selected programs will become active, allowing each program to be defined.
Enable Loudness Monitoring
turns all loudness monitoring functions ON or OFF
RESET
resets the measurements, and places a segment marker in the log file (but only if
User Event
is selected in
the Segment Marker area).
RUNNING / PAUSE
shows the current status of the loudness monitoring.
•
Click the button to change the status.
•
PAUSE stops the measurement until the button is clicked again, but keeps the last value for logging and
measurement.
Segment Marker
Select the checkboxes corresponding to the events for which you want a segment marker inserted in the loudness log
file:
•
User Event – a manually-triggered RESET (but not a PAUSE).
•
GPI – a trigger received externally via GPI input. GPI6 can be configured to trigger a Loudness reset; the
control is located on the
Factory/Presets | GPI
tab (see section 5.18.4 on page 95)
•
Dialnorm change – a change in Dialnorm value in the incoming metadata stream.
•
Coding Mode Change – a change in the coding mode, either through the manual settings or detected in the
incoming metadata stream.
Note that segment marker triggers in one PGM will generate segment markers in the logs for all PGMs.
5.12.2 Loudness | PGM panel
Four PGM panels – PGM 1, PGM 2, PGM 3 and PGM 4 – are
available, each activated by selecting the appropriate checkbox
in the LOUDNESS-CONFIG panel.
Use these panels to define the programs whose loudness will
be monitored by this XVP-3901.
Program Settings
Operation Mode: Use the pulldown to select to source of the
program definition:
Manual:
Use the Manual Coding controls to define the
program channel
Path 1:
Use Path 1 as defined in the Dolby Metadata panel
(see section 5.10.1 on page 70)
Path 2:
Use Path 2 as defined in the Dolby Metadata panel
(see section 5.10.1 on page 70)
Figure 5.71 Loudness panel – PGM 1 tab