GUIDE TO INSTALLATION AND OPERATION
XVP-3901 |
77
Note
– If you attempt to save the card configuration to a User Preset when the Metadata generator settings do not
correspond to a Metadata Preset value (i.e. if the Current Generator Preset data box shows “Custom”), you will
trigger a warning because of the way the Metadata Generator settings are saved. See page 92 for a complete
explanation. You may need to return to this panel and save the “custom” settings into a Metadata preset before you
can save the card configuration to a User Preset.
•
Avoid this by getting in the habit of saving the Generator Metadata settings each time you change them.
The
Metadata Profiles…
button gives access to a panel that allows the user to copy the card settings from this XVP-
3901 to other XVP-3901 cards accessible via iControl. These profiles are also compatible with the DAP-1781
metadata profiles.
Figure 5.66 Metadata Profile Copy window
The
Copy profile from
line shows the current XVP-3901 card.
•
The Profiles column contains a pulldown that lists the profiles that are available to copy.
•
The list includes the two generators, plus the 10 metadata presets
You can save the selected profile to disk for future recall:
•
Click the
Save profile to disk…
button and select a disk location and file name to save the file.
You can recall a previously-saved profile from disk and load it into the card:
•
Click the
Restore profile from disk…
button and find the appropriate file
•
Click
Open
to load the contents of the file into the current XVP-3901
The
Copy profile to
area shows all other XVP-3901 cards that have been detected on the iControl network.
•
The Profile column will show the same profile that was selected for the current XVP-3901 in the Profile
pulldown.