4. Installation
MiR Hook 100 Operating guide (en) 02/2020 - v.2.1 ©Copyright 2016-2020: Mobile Industrial Robots A/S.
19
2.
Mount the frame with the four bolts. Tighten the bolts with a torque of 47 (Nm) / [34.5 ft-
lb].
3.
Connect cables and mount the antenna:
Pos.
Description
Pos.
Description
1
Network cable (from robot to
hook PC)
2
Application hardware cable
3
Emergency stop cable
4
USB cable for top camera
5
Antenna connector